Battery charger maintenance, Delta-q - battery charger specs -8 – JLG M4069 Service Manual User Manual

Page 36

Advertising
background image

SECTION 3 - CHASSIS & SCISSOR ARMS

3-8

– JLG Lift –

3121824

Battery Charger Maintenance

USE CHARGER ONLY ON BATTERY SYSTEMS WITH AN ALGO-
RITHM SELECTED THAT IS APPROPRIATE TO THE SPECIFIC
BATTERY TYPE. OTHER USAGE MAY CAUSE PERSONAL INJURY
AND DAMAGE.

LEAD ACID BATTERIES MAY GENERATE EXPLOSIVE HYDRO-
GEN GAS DURING NORMAL OPERATION. KEEP SPARKS,
FLAMES, AND SMOKING MATERIALS AWAY FROM BATTERIES.
PROVIDE ADEQUATE VENTILATION DURING CHARGING. NEVER
CHARGE A FROZEN BATTERY.

STUDY ALL BATTERY MANUFACTURERS’ SPECIFIC PRECAU-
TIONS SUCH AS RECOMMENDED RATES OF CHARGE AND
REMOVING OR NOT REMOVING CELL CAPS WHILE CHARGING.

RISK OF ELECTRIC SHOCK. CONNECT CHARGER POWER CORD
TO AN OUTLET THAT HAS BEEN PROPERLY INSTALLED AND
GROUNDED IN ACCORDANCE WITH ALL LOCAL CODES AND
ORDINANCES. A GROUNDED OUTLET IS REQUIRED TO REDUCE
RISK OF ELECTRIC SHOCK - DO NOT USE GROUND ADAPTERS
OR MODIFY PLUG. DO NOT TOUCH UN-INSULATED PORTION OF
OUTPUT CONNECTOR OR UN-INSULATED BATTERY TERMI-
NAL. DISCONNECT THE AC SUPPLY BEFORE MAKING OR
BREAKING THE CONNECTIONS TO THE BATTERY WHILE
CHARGING. DO NOT OPEN OR DISASSEMBLE CHARGER. DO
NOT OPERATE CHARGER IF THE AC SUPPLY CORD IS DAM-
AGED OR IF THE CHARGER HAS RECEIVED A SHARP BLOW,
BEEN DROPPED, OR OTHERWISE DAMAGED IN ANY WAY -
REFER ALL REPAIR WORK TO QUALIFIED PERSONNEL. NOT
FOR USE BY CHILDREN.

1. For flooded lead-acid batteries, regularly check

water levels of each battery cell after charging and
add distilled water as required to level specified by
battery manufacturer. Follow the safety instructions
recommended by the battery manufacturer.

2. Make sure charger connections to battery terminals

are tight and clean.

3. Do not expose charger to oil or to direct heavy water

spraying when cleaning vehicle.

Table 3-3. Delta-Q - Battery Charger Specs

BATTERY CHARGER

SPECIFICATION

OUTPUT
Nominal DC Output Voltage

48V

Maximum DC Output Voltage 52V
Maximum DC Output Current 20A
Maximum Interlock Current 1A
INPUT
AC Input Voltage

85-265VAC

Nominal AC Input Voltage

120VAC - 230VAC RMS

AC Input Frequency

45-65 HZ

Maximum AC Input Current

12A RMS@108VAC

OPERATION
Charging Indicator

Yellow LED

100% Charge Indicator

Green LED

Fault Indicator

Red LED

External Temp Sensor

Automatic - Input wire/Output Connector

PROTECTION
Output Reverse Polarity

Electronic Protection - Automatic Reset

Output Short Circuit

Electronic Protection - Automatic Reset

AC Overload

Current Limited

DC Overload

Current Limited

MECHANICAL

Operating Temperature

–22°F to +122°F
(–30°C to +50°C)

Housing

Shock and Water Resistant Aluminum

Advertising