JLG 660AJ Service Manual User Manual
Page 290

SECTION 6 - JLG CONTROL SYSTEM
6-36
– JLG Lift –
3121616
FUNCTION CUT-
OUT:
18*
0
1
2
3
NO: No drive cutout.
BOOM CUTOUT: Boom function cutout while driving above elevation.
DRIVE CUTOUT: Drive cutout above elevation.
DRIVE CUT E&T: Drive cutout above elevation and tilted.
0
* Only visible under certain market selections.
* Certain market selections will limit function cutout options or alter default setting.
GROUND ALARM:
19*
0
1
2
3
NO: No ground alarm installed.
DRIVE: Travel alarm sounds when the drive function is active (Option).
DESCENT: Descent alarm sounds when lift down is active (Option).
MOTION: Motion alarm sounds when any function is active (Option).
3
* Certain market selections will alter default setting.
DRIVE:
20*
0
1
2
4 WD: Four wheel drive.
2WD: Two wheel drive.
2WD W/2-SPEED: Two wheel drive with two-speed valve.
0
* Only visible under certain market selections.
DISPLAY UNITS:
21*
0
1
IMPERIAL: DEG F, PSI, LBS
METRIC: DEG C, KPA, KGS.
0
* Certain market selections will alter default setting.
LEVELING MODE:
22*
0
1
ALL: Platform level with all functions.
LEVEL LIFT /TELESCOPE: Platform level on lift and telescope only.
0
* Only visible on 800S models.
DRIVE CONTROL:
23
0
1
2
NORMAL: Drive coils are energized from the Ground Module.
PROPULSION: Drive coils are energized from the Propulsion Module.
ENHANCED: Drive coils are energized from the Ground Module and the
ground side of the drive coils are brought back to current feedback returns.
2
BOOM CONTROL:
24
0
1
NORMAL: Boom control coils are energized from the Ground Module.
ENHANCED: Boom control coils are energized from the Ground Module and
the ground side of the drive coils are brought back to current feedback
returns.
0
Table 6-5. Machine Configuration Programming Information
Configuration Digit
Number
Description
Default
Number