Jumper

Function

B5 open*
B5 closed

no connection GND and chassis
GND and chassis connected

Slide switches

Function

S1 in position 1

T-Loop passive

S2 in position 1

R-Loop passive

S1 in position 2*

T-Loop active

S2 in position 2*

R-Loop active

DIP switches

Function

S3.1 closed / S3.2 open

level position RDY

S3.1 open / S3.2 closed*

level position RDY\

S3.3 open / S3.4 closed

connects RDY or RDY\ with Pin 2 or T-Loop

S3.3 closed / S3.4 open*

connects TxD with Pin 2 or T-Loop

S4.1 closed*

Signal RDY or RDY\ on Pin 25

S4.2 open*

protect resistor in R-Loop is activated

S4.3 open*

protect resistor in T-Loop is activated

S4.4 closed

in RS232C mode

S4.4 open*

in TTY 20 mA mode

Wrong settings/combinations can destroy components
and/or lead to malfunctions (e.g. sporadic transmission
errors)!