Tally Dascom 2610

103

Protocols

Memory mode XON/XOFF

The received characters are stored in a FIFO buffer (first in/first out).

The characters are processed in this buffer.

The buffer capacity can be adjusted from 0 to 128 Kb.
If the buffer is full, the interface signals NOT READY (signal acknowledgement: Level 1, -12 V)

and XOFF (hex. 13, dec. 19). This results in stopping the data transmission. When the FIFO

buffer is empty again, the interface signals READY (level 0, +12 V) and XON (hex.11, dec. 17).

Data transmission can be continued.
In addition, the READY signal is influenced by the status of the printer (On/Off Line). If the

printer assumes an undefined state, the interface also signals NOT READY and XOFF.
Memory mode Robust XON/XOFF

Robust XON/XOFF is similar to XON/XOFF. However, the state of the printer (XON or XOFF)

is also periodically transmitted via the TxD line in the case of Robust XON/XOFF.
Extended menu functions with the ENQ/STX and ETX/ACK protocols selected