3 system status table mgb-ap, System status table mgb-ap – EUCHNER MGB-L0-xxxAPx-xxx User Manual
Page 31

31
Operating Instructions MGB-L0...AR.-... and MGB-L0...AP.-...
13.3 System status table MGB-AP
Operating mode
Door position
Position of the bolt
tongue
Safety outputs FO1A
and FO1B
Door monitoring
output (OD)
Belt tongue monitoring
output (OT)
Diagnostic monitoring
output (OI)
LED indicator
State
Power (green)
State (green)
DIA (red)
Normal opera
-
tion
open
not inser
ted
OFF
OFF
OFF
OFF
Long OFF
shor
t ON
Normal operation, door open
closed
not inser
ted
OFF
ON
OFF
OFF
Long ON,
shor
t OFF
Normal operation, door closed
closed
inser
ted
ON
ON
ON
OFF
Normal operation, door closed, bolt tongue inser
ted. Safety outputs FO1A and FO1B ar
e ON
Teach-in standby
(only for
MGB unicode
open
not inser
ted
OFF
OFF
OFF
OFF
3 x
Door open; unit is r
eady for teach-in for another handle module (only 3 min. after power-up)
Setup
(only for
MGB unicode
closed
inser
ted
OFF
OFF
OFF
OFF
2 Hz
Teach-in operation, tip: T
o pr
event the interruption of teach-in operations, close door and inser
t bolt tongue.
X
X
OFF
OFF
OFF
OFF
Positive acknowledgment after completion of teach-in operation
Diagnostics
X
X
OFF
OFF
OFF
ON
1 x
Err
or during configuration or invalid DIPswitch setting
X
X
OFF
X
X
OFF
3 x
Handle module r
ead err
or (e.g. err
or in code)**
X
X
OFF
OFF
OFF
ON
4 x
Output err
or (e.g. shor
t cir
cuits or loss of switching capability) or shor
t cir
cuit at the outputs*
X
X
OFF
OFF
OFF
ON
Internal fault (e.g. component faulty
, data fault)*
X
X
OFF
OFF
OFF
ON
Signal sequence err
oneous (e.g. br
oken bolt tongue) ***
X
X
X
X
X
X
Power is ON for a very long
time with shor
t interruption
1 million operating cycles exceeded
*
Latching fault; to r
eset, use the RST input or briefly disconnect the device fr
om the power supply
**
Non-latching fault; open safety guar
d and close it again to r
eset
***
See section
roubleshooting and assistance, page 32
Impor
tant
: If you do not find the displayed device status in the System status table, this indicates an internal device fault. In this case, you should contact the manufactur
er
.