Operating Instructions MGB-L0...AR.-... and MGB-L0...AP.-...

13.3 System status table MGB-AP

Operating mode

Door position

Position of the bolt

tongue

Safety outputs FO1A

and FO1B

Door monitoring

output (OD)

Belt tongue monitoring

output (OT)

Diagnostic monitoring

output (OI)

LED indicator

State

Power (green)

State (green)

DIA (red)

Normal opera

-

tion

open

not inser

ted

OFF

OFF

OFF

OFF

Long OFF

shor

t ON

Normal operation, door open

closed

not inser

ted

OFF

ON

OFF

OFF

Long ON,

shor

t OFF

Normal operation, door closed

closed

inser

ted

ON

ON

ON

OFF

Normal operation, door closed, bolt tongue inser

ted. Safety outputs FO1A and FO1B ar

e ON

Teach-in standby

(only for

MGB unicode

open

not inser

ted

OFF

OFF

OFF

OFF

3 x

Door open; unit is r

eady for teach-in for another handle module (only 3 min. after power-up)

Setup

(only for

MGB unicode

closed

inser

ted

OFF

OFF

OFF

OFF

2 Hz

Teach-in operation, tip: T

o pr

event the interruption of teach-in operations, close door and inser

t bolt tongue.

X

X

OFF

OFF

OFF

OFF

Positive acknowledgment after completion of teach-in operation

Diagnostics

X

X

OFF

OFF

OFF

ON

1 x

Err

or during configuration or invalid DIPswitch setting

X

X

OFF

X

X

OFF

3 x

Handle module r

ead err

or (e.g. err

or in code)**

X

X

OFF

OFF

OFF

ON

4 x

Output err

or (e.g. shor

t cir

cuits or loss of switching capability) or shor

t cir

cuit at the outputs*

X

X

OFF

OFF

OFF

ON

Internal fault (e.g. component faulty

, data fault)*

X

X

OFF

OFF

OFF

ON

Signal sequence err

oneous (e.g. br

oken bolt tongue) ***

X

X

X

X

X

X

Power is ON for a very long

time with shor

t interruption

1 million operating cycles exceeded

*

Latching fault; to r

eset, use the RST input or briefly disconnect the device fr

om the power supply

**

Non-latching fault; open safety guar

d and close it again to r

eset

***

See section

14 T

roubleshooting and assistance, page 32

Impor

tant

: If you do not find the displayed device status in the System status table, this indicates an internal device fault. In this case, you should contact the manufactur