Pin assignment, Technical data, Read head with connection cable – EUCHNER CES-A-AEA-04B (Unicode) User Manual
Page 30: Ordering table

Operating Instructions Safety System CES-A-AEA-02B/CES-A-AEA-04B
30
Pin assignment
Read head with connection cable
Technical Data
Parameter
Value
Unit
min.
typ.
max.
Housing material
Plastic PE-HD without reinforcement, fully encapsulated
Flat seal material
Fluororubber 75 FPM 4100
Dimensions
42 x 25 x 12
mm
Weight (incl. 10 m cable)
0.3
kg
Ambient temperature
-25
-
+50
°C
Degree of protection
IP67/IP69K
Installation position
Any
Method of operation
Inductive
Power supply
Via evaluation unit
In combination with actuator CES-A-BBA on evaluation unit CES-A-AEA...
Assured switch-off distance S
ar
-
-
32
mm
Operating distance for center offset m = 0
1)
- Switch-on distance
-
15
-
- Assured switch-on distance S
ao
10
-
-
- Switching hysteresis
0.5
2
-
Minimum distance s with lateral approach direction
-
3
-
In combination with actuator CES-A-BDA on evaluation unit CES-A-AEA...
Assured switch-off distance S
ar
-
-
33
mm
Operating distance for center offset m = 0
2)
- Switch-on distance
-
16
-
- Assured switch-on distance S
ao
11
-
-
- Switching hysteresis
0.5
2
-
Minimum distance s with lateral approach direction
-
4
-
Connection cable
Hard-wired encapsulated connection cable, with crimped ferrules
PVC,
∅ 4.6 mm
Cable length
-
-
25
m
1)
These values apply to non-flush installation of the read head and actuator.
2)
These values apply to metal-free surrounding material. Other materials on request.
Ordering table
Series
Cable/connection type
Cable length "l" [m]
Order no. / item
CES-A-LCA...
V
Cable PVC
10
088785
CES-A-LCA-10V
H11 H12 SH1
BN
WH
Screen
View on the plug
connector of the
read head
Evaluation unit
CES-A-AEA...
Read
head