3 electrical connection 103374, Electrical connection 103374, Terminal signal / description – EUCHNER AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor for 2 AS-i circuits User Manual
Page 45: Information

AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor
Electrical connection
Subject to reasonable modifications due to technical advances
Id.-No.: 103329
Issue date - 24.10.2008
EUCHNER GmbH + Co. KG
45
Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen
Tel. +49/711/75 97-0 • Fax. +49/711/753316
7.4.3
Electrical connection 103374
+
-
+
-
+
-
+ASI
1–
+
Gateway
Safety Monitor
+ASI
2–
ASI
1 +PWR– (max. 8A)
ASI 2 +PWR– (max. 8A)
M4
5 mm max!
Function ground
Terminal
Signal / Description
+ASI 1–
Connection to AS-i Circuit 1
+ASI 2–
Connection to AS-i Circuit 2
ASI 1 +PWR–
Supply voltage for AS-i Circuit 1 (max. 8 A)
ASI 2 +PWR–
Supply voltage for AS-i Circuit 2 (max. 8 A)
FG
Function ground
Information!
AS-i Circuits 1 and 2 are powered by separate power supplies.
Information!
For additional information, please refer to the section <AS-i and power supply terminal