network.

Managed head: displays the managed head type.

Head Serial Number: This is the head serial number and during the Activation
process we will ask for this number.

9.1.3 Status info screen


Clicking on the Device Setup you will enter the main status information screen, which
will give you good summarized information of the device, such as status information
of the transmitters, detector level, or temperature values.

Laser ON: Transmitter transmitts

Laser OK: Transmitter works properly, transmitts and the transmitted signal is valid.

Temperature: ambient temperature inside the device. These units were designed for
extreme conditions and should not have any problems under -60C to +80C. In fact
the unit is emitting some heat so the temperature displayed is not the air temperature
outside the head. For example the temperature can be -10C outside but in the device
it wont go below -1 or -2. The value will display error depeding on the setting was
done device setup. There is no default value for this setting, only a suggested value,
which is 60C.

Detector level: shows the local heads received level. In volts, the maximum is 7 volts
and the minimum is 0.2 volts. The value will display error depeding on the setting
was done device setup.

Remote Detector level: this value is dispalyed form reception of the remote head.
The maximum is 7 volts and the minimum is 0.2 volts.

TP_Link: displays that there is connection over the TP cable.

FSO Link: displays that there is valid signal received from the remote end.

Remote is visible: this status information is a good information about the connection
over the two laserheads if this status is OK that means that there is data transferred
over the link.

Remote TP Link: shows that whether the remote end is connected into the switch
and the TP interface is available.

PSU: The PSU of the device is sending the OK signal.