CONFIGURATION 6:

EXTENDED PAGING SYSTEM

This illustration shows the wiring between a master assembly and a satellite assembly in a PCM system with a satellite assembly for one-way paging.
As described previously, the required setup for one-way basic configuration includes: PCMTIM, PCMCPU, PCMZPM, and the power supply
PCMPS2. For PCM systems with satellites (more than 9 zones), the number of modules and power supplies will increase as follows:

# ZONES

# PCMTIM

# PCMCPU

# PCMZPM*

# PCMPS2

1

to 9

1

1

1

to 3

1

1

0 to 18

1

2

4 to 6

2

1

9 to 27

1

3

7 to 9

3

28 to 36

1

4

1

0 to 12

4

37 to 45

1

5

1

3 to 15

5

46 to 54

1

6

1

6 to 18

6

55 to 63

1

7

1

9 to 21

7

64 to 72

1

8

22 to 24

8

73 to 81

1

9

25 to 27

9

82 to 90

1

1

0

28 to 30

1

0

91 to 99

1

11

31 to 33

11

Notice that for every 9 zones, one additional PCMCPU and one additional PCMPS2 are needed.
* 1 PCMZPM for every 1-3 paging zones.
INSTALLATION:
STEP 1: Assembling Master Modules PCMTIM to PCMCPU and to PCMZPM

Follow the same procedure described previously on page 5, step 1.
Note: Do NOT connect the PCMPS2 (power supply) at this point.

STEP 2: Assembling Satellite Modules PCMCPU to PCMZPM (see Illustration on page 38)

Plug the 6-pin power connector from the PCMZPM module to the PCMCPU module jack (J2.) Be sure that the locking ridge faces the
header wall. (Green wire to the top).

Plug the 26-pin ribbon cable from the PCMZPM module to the PCMCPU module 26-pin connector (J1). Be sure to align the polarizing
tab in slot. (Pin 1 red stripe to the top).

The satellite systems are usually installed below the the master assembly and must be within 3 feet of each other.

Use an RCA cable to connect the PCMCPU modules from DATA LINK to DATA LINK RCA connectors. (See drawing.)

STEP 3: Switch Settings

Set the TEL-INT-SEL DIP switches on the PCMTIM module to match the paging output access from the telephone system based on the
type of telephone interface used. (See step 3 on page 5 if using Page Port Contact Closure; page 7 for Page Port VOX; page 9 for Loop
Start Trunk; page 11 for Ground Start Trunk; or page 13 for Station Level/Centrex.)

Set the SYS-ID DIP switches on the master PCMCPU module to the OFF position (to the left).

Set the SYS-ID DIP switches on the first satellite PCMCPU module to the following configuration: Switch 1 to the ON position (to the
right). Switches 2, 3, & 4 to the OFF position (to the left). See SYS-ID switch settings chart on page 38 for additional satellite systems.

Set the RUN-PROGRAM switch on the PCMCPU module to the RUN mode (up).

Set the TALK BACK switches on the PCMZPM modules to the OFF position (to the left) for all zones.

Set the OUTPUT switch on all the PCMZPM modules to the HI-PWR position (down).

STEP 4: Testing your System

Connect one PCMPS2 power supply to each PCMCPU module either by the power jack 12V DC input or wire it to the 12V DC screw
terminals, observing polarity.

At this point all the power LEDs should be lit on each module.

Access the paging from the phone system and verify access tones (double beep).

At this point, the system should be functioning properly.

Disconnect Power Supply.

STEP 5: Connecting the Paging Amplifier

Locate the terminals on both PCMCPU modules labeled PA OUT/RT and wire them to the COMMON and 25V or 70V output on the
Bogen paging amplifier (either TPU-Series, GS-Series or Classic Series).

Locate the terminals on the PCMCPU modules labeled PA IN/RT and wire to the TIP and RING input on the Bogen paging amplifier.At
this point, the amplifier is connected in parallel to the master PCMCPU module and the satellite PCMCPU module.

STEP 6: Connecting 25/70V AC Speakers

Follow the same procedure described previously on page 5, step 6.

STEP 7: Testing your System

Follow the same procedure described previously on page 5, step 7.

26

15

PCM

TIM

PO

WER

TO

N

E

V

OLUME

BGM SRC

V

OLUME

GND ST

IN

RT

BGM

SRC

NIGHT

RING

TEL

LINE

O

VER

RIDE

NC

COM

NO

NC

COM

NO

RL

Y

ONE

RL

Y

TW

O

S1

S2

S3

S4

S5

S6

S7

TEL

INT

SEL

0 1

G

BK

R

Y

BL

W

Not used

Pla

y status contact common

A

udio output (-)

A

udio output (+)

Pla

y status contact

Not used

6 CONDUCT

OR

MODULAR

CABLE

RJ 11

MODULAR

BO

X

8

600

DL

LS

V

OLUME

1 6

1 6

1 2 3 4 5 6 7 8 9 101112

1 2 3 4 5 6 7 8 9 10 11 12

IN USE PLA

Y RECORD

PO

WER

12VDC 1A

COMPLIES

WITH P

AR

T 68, FCC R

ULES

FCC REGISTRA

TION NUMBER:

CD23CH-17705-KX-N

RINGER EQ

UIV

ALENCE:

1.2 B

T

AM B

TELEPHONE A

CCESS

MODULE

BOGEN

COMMUNICA

TIONS

RAMSEY

, NJ

MODE

24

VDC PWR SUPPL

Y

48

VDC PWR SUPPL

Y

CONFIRMA

TION T

ONE

PREANNOUNCE T

ONE

V

O

X DISABLE

V

O

X ENABLE

OFF

-----

S1, S2

S3

S4

S5

-----

ON

S1, S2

-----

S4

S3

-----

S5

PHONE SYSTEM

T

R

+M

-M

EXT V

O

X

ENABLE

PT

PR

P

A

GING OUTPUT

N.O

.

COM

CONT

A

CT CLOSURE A

+24/48

-24/48

PO

WER SUPPLIES

MODE

SWITCHES

BGM

VO

L

.

BGM

IN

TO

N

E

VO

L

U

M

E

MIN

MAX

V

O

X DELA

Y

MIN

MAX

P

A

GING TIME

MIN

MAX

OFF ON

G

BK

R

Y

BL

W

DFT120

PBX

ANALOG LINE

Note Switch settings:

Off - Up

, On - Do

wn

24/48V DC

PO

WER

SUPPL

Y

SETUP FOR CONFIGURATION 12: DFT120 & TAMB WIRING DIAGRAM - LOOP START TRUNK, GROUND START TRUNK OR STATION LEVEL