Parameter list | C13010
C13010
C13011
C13012
C13013
C13014
Parameter | Name:
C13010 | Encoder type DFIN
Data type: UNSIGNED_8
Index: 11565
d
= 2D2D
h
Digital frequency extension module in module receptacle MXI1:
Selection of the encoder type for digital frequency input X9
Selection list
(Lenze setting in bold)
1 Digital frequency output DFOUT
2 TTL encoder
;
Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C13011 | No. of increments DFIN
Data type: UNSIGNED_32
Index: 11564
d
= 2D2C
h
Digital frequency extension module in module receptacle MXI1:
Number of increments for digital frequency input X9
• Definition of the number of pulses for one "mechanical" revolution.
Setting range
(min. value | unit | max. value)
Lenze setting
1
16384 2048
;
Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C13012 | Signal format DFIN
Data type: UNSIGNED_8
Index: 11563
d
= 2D2B
h
Digital frequency extension module in module receptacle MXI1:
Signal form for digital frequency input X9
• Selection of how to interpret the input signal.
Selection list
(Lenze setting in bold)
0 4x evaluation (A, B)
1 A:Increments B:Sign
2 Increments A:pos. B:neg.
;
Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C13013 | Initialisation time DFIN
Data type: UNSIGNED_16
Index: 11562
d
= 2D2A
h
Digital frequency extension module in module receptacle MXI1:
Initialisation time for digital frequency input X9
• Waiting time after which the "Enable" signal is evaluated and the track monitoring modes are switched active.
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
65535 3000 ms
;
Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C13014 | Track monitoring DFIN
Data type: UNSIGNED_8
Index: 11561
d
= 2D29
h
Digital frequency extension module in module receptacle MXI1:
Monitoring configuration for digital frequency input X9
• Selection when track monitoring modes (open circuit detection) are active.
Selection list
(Lenze setting in bold)
1 Active after initialisation time
2 Active after enable signal
;
Read access ; Write access CINH PLC-STOP No transfer