Layout of the front and rear panel – Longevity FORCECUT 42i User Manual
Page 12
ForceCut 42i 110v/220v PFC 40amp Plasma Cutter
12
Layout Of The Front And Rear Panel
1.
Power Light: The light will illuminate when the unit is powered on
2.
Temperature /Over-Heat Light: When the duty cycle is reach, the TEMP will turn on. Once it is safe to operate
the machine, the light will turn off. If duty cycle is reached, allow machine to run with the fan on to accelerate
cooling.
3.
Tip/Air Light
When adequate air pressure is reached, the Tip/Air light should turn on
4.
Pilot/Voltage Light: The Pilot/Voltage light is illuminated when the machine is ready to use.
5.
Amperage Control Knob: Allows the user to precisely set the desired amperage output. The machine is
limited to 30A when connected to 110v power supply
6.
RUN/SET: When cutting the, turn the switch to “RUN”; when doing a gas test, turn to the “SET”.
7.
Cutting gun connector: Connector for the PT-60 plasma torch
8.
Ground Clamp: Connect to the workpiece or a secure ground
9.
Power Cable: connect to the desired power supply(110v/220v)
10. Power Switch turns on or off the machine
11. Air connector (Note: air pressure had setted inside. That is 4bar/60psi)