Installation

d

eciding

W

here

to

l

ocate

your

p

ellet

a

ppliance

:

1. Unit must be installed in a masonry fireplace.
2. Do not install the stove in a bedroom or room where people sleep in.
3. Locate the stove in a large and open room that is centrally located in the house. This will optimize

heat circulation.

4. Check clearances to combustibles and for the least amount of interference to house framing, plumbing,

wiring, etc.

5. You can vent the stove with approved flex pipe.
6. This unit uses large quantities of air for combustion; outside Fresh Air connection is strongly

recommended. Fresh Air must be connected to all units installed in Mobile and “Air Tight Homes”

(R2000) or where required by local codes.

7. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may be

obtained from a ventilated crawlspace.

8. The power cord is 8 feet (2.43 m) long and may require a grounded extension cord to reach the

nearest electrical outlet.

r

emoving

p

ellet

S

tove

f

rom

p

allet

:

1. Remove the wooden crating surrounding the unit.

2. Remove the cast top, cast sides, cast front, and the cast ash shelf.

3. Unclip the unit from the lower frame.

4. Slide the unit forward and

then out.

5. Remove the two top bolts

on the pallet mounting

plates as shown in Fig. 3.

6. Remove entire frame as

one piece.

figure 3: Mounting plates securing stove to pallet

Hampton GCI60 Cast Pellet Insert Technical Manual