Rockwell Automation 42JS Series 7000 to 42JS VisiSight Replacement Kit User Manual

Wiring considerations (cable models only)

Advertising
background image

Installation Instructions

Series 7000 to 42JS VisiSight™ Replacement Kit

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

Description

The R7KJS replacement kits are designed to facilitate the
transition of the Series 7000 photoelectric sensors to the
42JS VisiSight product family. The small-footprint stainless
steel bracket included in the kit allows the user to securely
mount the 42JS VisiSight using the existing Series 7000
mounting holes.

The kit includes:

• 42JS VisiSight sensor
• Left-side mounting bracket
• Right-side mounting bracket
• Mounting hardware (M3 screws and P1 nut)
• Mounting hardware for 60-2619 (4-40 screws)

To install the 42JS VisiSight:

1. Uninstall and remove the Series 7000 photoelectric sensor

from your machine.

2. Select the left or right mounting bracket as appropriate.

3. Insert the tab on the bracket into the top mounting hole of

the 42JS VisiSight.

4. Hold the mounting bracket and 42JS VisiSight in position

on the mounting surface, aligned with the mounting holes.

5. Secure with the short and long M3 screws and the P1 nut

provided, as shown.

.

Wiring Considerations (Cable Models Only)

The cable models of the Series 7000 use a different wire
color code from the 42JS VisiSight. To wire the 42JS
VisiSight cable models in a Series 7000 cable model
application you have to use the color code below.

For mounting the 42JS VisiSight on the
60-2619 swivel/tilt bracket, use the
60-BJS-L2 bracket (sold separately) to
secure the 42JS VisiSight.

When installing transmitted beam
sensors, replace both the transmitter and
receiver with those supplied in the kit.

Series 7000
(existing installation)

42JS VisiSight
(new installation)

+V

Red

Brown

–V

Black

Blue

LO

Green

Black

DO

White

White

IMPORTANT

IMPORTANT

Remove Series 7000

photoelectric sensor

Left-side

mounting

bracket

42JS

VisiSight

sensor

P1 nut

(for M3 screws)

LED indicator
on back

LED indicators
on top

Mounting

surface

Left-side mounting

Remove Series 7000

photoelectric sensor

Right-side

mounting

bracket

42JS

VisiSight

sensor

P1 nut

(for M3 screws)

Mounting

surface

Right-side mounting

Advertising