Indicators, 30 fo – BenQ PE6800 User Manual

Page 30

Advertising
background image

30

Additional Information

Indicators

There are three indicators which show the status of the projector. Check the following for information about the
indicator lights. If there is anything wrong, turn the projector off and contact your dealer.

When the projector is in a normal state, ...

When the projector is in an abnormal state, ...

POWER

LAMP

TEMP

STATE

REMARK

Orange

Off

Off

Standby mode.

Flashing
Green

Lamp standby mode.

Cannot turn the projector off.

Green

Power on.

Flashing
Orange

Lamp is cooling down.

Cannot turn the projector on.

POWER

LAMP

TEMP

STATE

REMARK

Orange

Off

Red

The internal temperature is too
high.

The intake ventilation or the
exhaust ventilation is blocked.

The projector may be in a
poorly ventilated location.

The ambient temperature may
be too high.

Solution:

Make that the ventilation
holes are not blocked.

Relocate the projector.

Stop using the projector until
the ambient temperature falls
within the specified range.
The maximum operating
temperature is specified as
35°C / 95°F.

Red

Off

The projection circuit is working ,
or the lamp is abnormal.

Solution:

Restart the projector.

If this operation is repeated several

times and the lamp indicator remains in

red, replace the lamp and contact your

dealer for assitance.

Green

Flashing
Red

Off

Almost time to to replace the lamp.
The lamp has been used for 1000
hours. (The power is on.)

Solution:

Install a new lamp.

Orange

Almost time to to replace the lamp.
The lamp has been used for 1000
hours. (The power is off.)

Red

Time to to replace the lamp. The
lamp has been used for 1500 hours

Flashing
Red

Flashing
Red

The cooling system has a problem.

Contact your dealer.

Advertising