Kino Flo Mega 4Bank DMX (BAL-450M) User Manual

Page 9

Advertising
background image

9




















A) Circular Output Connector: Provides electrical power to the

lamp head with the use of a 4Bank extension cable.

B) DMX-In & DMX-Out: DMX-IN receives DMX signals from Dimmer

Board. DMX-OUT relays DMX signal through to other Fixtures or
Instruments.

C) Fuse: Provides circuit protection. Note: If Fuse is "blown" or

"open" replace with same type of fuse rating as marked.

D) DMX TERMINATE Switch: Terminates DMX signal at the end

of Fixture series.

E) DMX Address: Sets DMX Address of Fixture.

F) Individual Lamp / Fixture Switch: Converts between

INDIVIDUAL LAMP and FIXTURE methods of DMX control.

G) Lamp Select: Set to HO for burning lamps at high output and

STD for burning lamps at Standard Light Output.

H) Manual Switches: Turns lamps on and off manually.




A

E

F

G

H

B

D

C

Lamp Select feature continued…
When operating 8 or 6ft lamps in high ambient temperature or where the
units are rigged into place with restricted airflow, the STD setting can be
used to lower the color temperature and remove any green spike.
The light drops about a half an f-stop in exposure when dropping from
HO to STD.

Advertising