11
GB
SYMPTOM
PROBLEM
SUGGESTED REMEDY
Motor overheats
Motor overloaded
Reduce load on motor. Turn off the machine
until motor cools down
Excessive dust build-up results in
decreased air circulation
Remove dust build-up
Frequent tripping of circuit
breaker
Motor overload
Reduce load on motor
Inadequate capacity of circuit breaker Replace with correct circuit breaker
Circuit overload
Reduce circuit load
Blades are dull
Sharpen or replace blades
Snipe
Inadequate support of workpiece
Support long workpiece with additional
platform
Blades are dull
Replace blades
Uneven force on cutterhead
Push workpiece gently during operation
Rollercase is not parallel with table
Adjust table and rollercase level correctly
Workpiece is not butted correctly
Butt end to end each workpiece as it passes
through planer
Planed surface not smooth
Blades are dull
Replace blades
Fuzzy grain due to high moisture
content in wood
Use dry wood
Torn grain due to blades cutting
against grain
Change direction and feed workpiece along
the grain
The cut is too deep
Decrease depth of cut
Uneven thickness from side to side
Rollercase is not positioned level with planer
base. Adjust rollercase alignment
Difficulties in adjusting
rollercase height
Rollercase lock is engaged
Release rollercase lock
Worn elevation screws
Replace elevation screws
Dirty elevation screws
Clean and lubricate elevation screws
Rollercase is not positioned parallel
with table
Re-align rollercase
Friction between rollercase and side
panels
Clean and adjust rollercase
TROUBLESHOOTING
Troubleshooting