Tweco Thermal Arc TA 500 User Manual
Page 16

General Information
1-2
Manual No 0-0470
42"
(106.7 cm)
47"
(119.4 cm)
32"
(81.3 cm)
TAC 500 Dimensions
C. Supply Console
• Power Input: From 500 Power Supply
• Plasma and Secondary Gas Pressure: Controlled by
pressure regulator at gas supply
• Secondary Water Flow: Controlled by a flow meter
on front panel
• Torch Coolant: From HE 200 Coolant Recirculator
• Weight: 50 lbs. (22.7 kg)
9-3/4"
(25 cm)
16-5/8"
(42.2 cm)
19"
(48 cm)
Supply Console Dimensions
D. HE 200 Coolant Recirculator
• Power Input: 50 or 60 Hz, 3 phase in one of the fol-
lowing standard voltage/amperage combinations:
1- 230 volts, 60 Hz, 5.5 amps
2- 460 volts, 60 Hz, 2.75 amps
3- 575 volts, 60 Hz, 2.2 amps
• Pump Capacity: 5.2 gpm (23.6 lpm)
• Capacity: 80,000 BTU/hr
• Weight: 263 lbs. (119.4 kg)
26"
(66 cm)
38-1/2"
(98 cm)
28"
(71 cm)
HE 200 Dimensions
E. Control Panel
• Power Input: from 500 Power Supply
• Weight: 15 lbs (6.8 kg)
9-5/8"
(24.4 cm)
8-1/4"
(21 cm)
Control Panel Dimensions