Ultra-cut 400, 07 system component layout – Tweco 400 Ultra-Cut User Manual

Page 18

Advertising
background image

SPECIFICATIONS 2-2

Manual No. 0-5164

ULTRA-CUT 400

2.07 System Component Layout

Ultra-Cut 400 Power Supply

Input

Power Input Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG) Wire (mm

2

)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

3-Ph

208

50/60

119

336

350

300MCM

150

230

50/60

119

304

350

250MCM

150

460

50/60

116

148

175

#1

50

380

50/60

120

183

225

1/0

70

400

50/60

120

174

225

1/0

70

* Suggested wire size based on United States NFPA 70 National Electrical Code 2005 edition

published by the National Fire Prevention Association.

Listings are from table 400.5(B) for flexible cord of certain types rated for 75 deg C in ambi-

ent temperatures up to 30 deg C. Using wires of lower temperature rating or different insula-

tion type may require larger wire size. Derate for higher ambient.

These are suggestions only. Always refer to your local and national codes that apply to your

region for final determination of correct wire type and size.

CNC

Art # A-09536

Control

Cable

Fiber
Optic

Cable

Control

Cable

Gas Control

Module

Torch

Valve

Assembly

Plasma Gas

Shield Gas

Plasma Gas

Shield Gas

Preflow Gas

Work

Torch

Positioning Tube

Water

Shield

Work Cable

175’ / 53.3 m Maximum Length

Primary power

Remote

Arc

Starter

Coolant Supply 10’

Coolant Return 10’

Control Cable

Pilot Return

Coolant Supply

Coolant Return

Ultra-Cut

Power
Supply

Shield

Negative Cable

Pilot Return #8

50’ / 15.25 m Maximum Length

Shield

125’ / 38.1 m Maximum Length

175’ / 53.3 m Maximum Length

HE 400
Heat
Exchanger

Control Cable

Coolant Supply

Coolant Return

GroundCable
Only when
GCM is
mounted on
top of PS.