Ultra-cut 400, 07 system component layout – Tweco 400 Ultra-Cut User Manual
Page 18

SPECIFICATIONS 2-2
Manual No. 0-5164
ULTRA-CUT 400
2.07 System Component Layout
Ultra-Cut 400 Power Supply
Input
Power Input Current
Suggested Sizes (See Note)
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps)
Wire (AWG) Wire (mm
2
)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
3-Ph
208
50/60
119
336
350
300MCM
150
230
50/60
119
304
350
250MCM
150
460
50/60
116
148
175
#1
50
380
50/60
120
183
225
1/0
70
400
50/60
120
174
225
1/0
70
* Suggested wire size based on United States NFPA 70 National Electrical Code 2005 edition
published by the National Fire Prevention Association.
Listings are from table 400.5(B) for flexible cord of certain types rated for 75 deg C in ambi-
ent temperatures up to 30 deg C. Using wires of lower temperature rating or different insula-
tion type may require larger wire size. Derate for higher ambient.
These are suggestions only. Always refer to your local and national codes that apply to your
region for final determination of correct wire type and size.
CNC
Art # A-09536
Control
Cable
Fiber
Optic
Cable
Control
Cable
Gas Control
Module
Torch
Valve
Assembly
Plasma Gas
Shield Gas
Plasma Gas
Shield Gas
Preflow Gas
Work
Torch
Positioning Tube
Water
Shield
Work Cable
175’ / 53.3 m Maximum Length
Primary power
Remote
Arc
Starter
Coolant Supply 10’
Coolant Return 10’
Control Cable
Pilot Return
Coolant Supply
Coolant Return
Ultra-Cut
Power
Supply
Shield
Negative Cable
Pilot Return #8
50’ / 15.25 m Maximum Length
Shield
125’ / 38.1 m Maximum Length
175’ / 53.3 m Maximum Length
HE 400
Heat
Exchanger
Control Cable
Coolant Supply
Coolant Return
GroundCable
Only when
GCM is
mounted on