Installation/setup fabricator 252i – Tweco 252i Fabricator User Manual
Page 43
INSTALLATION/SETUP
FABRICATOR 252i
Manual 0-5155
3-13 INSTALLATION/SETUP
Function
Left Display
Right Display
(Factory De-
fault Values)
Limits
Comments
Arc Hour Accu-
mulated Run-
time
HR
0.0
0.0 – 9999.9
Provides Arc On Hours that the power source has
welded. The number displayed is in hours and
read only. It will rollover to 0 once 10,000 hours
have been reached.
Restore Factory
Defaults
FACT/DFLT
NO
NO – YES
When YES is selected all the user adjustable val-
ues in this table (except Arc Hour Accumulated
Runtime) are reset to the Factory Default Values.
LIFT TIG Mode Advanced Features Menu Map
PRE- / FLOW
POST / FLOW
Advanced Menu -
LIFT TIG Mode
Press Advanced Button
to Exit to Welding Mode
FACT / DFLT
Left Knob Selection
Right Knob Selection
Left Display
Right Display
HR
TIG / CNTL
DOWN / SLPE
Advanced Menu - LIFT
TIG Options or Range
Press Advanced Button
to Exit to Welding Mode
0.0 - 5.0 S
LOCL REMT
NO YES
0.0 - 9999.9
0.0 - 30.0 S
0.0 - 30.0 S
Left Display: Where (2) items shown, e.g. RUN- / IN, the display will alternate (flash) between the (2) items
Art # A-10506_AB
TIG
Process
MIG
STICK
Advanced
Features
Figure 3-6: LIFT TIG Advanced Menu
Function
Left Display
Right Display
(Factory De-
fault Values)
Limits
Comments
LIFT TIG Opera-
tor Controls
LIFT TIG/
CNTL
REMT
LOCL - REMT
LOCL = Local control of the Amps with the
machines controls
REMT = Remote control of the Amps with an
accessory device
Pre Flow (LIFT
TIG Setting)
PRE-/FLOW
0.1 S
0.0 – 5 S
Shielding gas flows for the time specified before
an arc is initiated
Post Flow (LIFT
TIG Setting)
POST/FLOW
10.0 S
0.0 – 30 S
Shielding gas flows for the time specified after
an arc has extinguished