5 torch connections, 5 torch connections -6 – Tweco PC-500 User Manual
Page 24
INSTALLATION
3-6
Manual 0-4601
3.5
Torch Connections
If necessary, connect the torch to the Power Supply. Connect only the model SL60 torch (with ATC connector) to this
power supply.
WARNING
Disconnect primary power at the source before connecting the torch.
1.
Align the ATC male connector (on the torch lead) with the female receptacle. Push the male connector into
the female receptacle. The connectors should push together with a small amount of pressure.
2.
Secure the connection by turning the locking nut clockwise until it clicks. DO NOT use the locking nut to pull
the connection together. Do not use tools to secure the connection.
3.
The system is ready for operation.
ATC Female Receptacle
Art # A-03825
1
2
ATC Male
Connector
Torch Leads
Connecting the Torch to the Power Supply