Shield – Tweco XT-301 Torch Data for Distributor Use w- Auto-Cut 200 AF User Manual
Page 14
Torch Data
8-14
Manual 0-4806 Rev. AF
Stainless Steel
200A
H35 Plasma / N
2
Shield **
35-1273
Shield Cup
35-1016
Shield Cap
Shield Gas
Distributor
Tip
35-1058
Art # A-07610
Plasma Gas
Distributor
35-1043
< 1” (25mm)
1” + (25mm)
35-1032
Electrode
35-1087
Cartridge
35-1020
35-1031
>
Plasma
(H35)
Shield
(N
2
)
(ga)
(in)
inch
(PSI)
(PSI)
Volts
(in)
±0.005
(ipm)
(in)
(sec)
(in)
3/8
0.375
70
120
157
0.240
90
0.300
0.5
0.158
1/2
0.5
70
120
160
0.260
65
0.300
0.6
0.171
5/8
0.625
70
120
165
0.280
50
0.350
0.7
0.178
3/4
0.75
70
120
168
0.300
40
0.450
0.8
0.180
7/8
0.875
70
120
172
0.300
30
0.450
0.9
0.178
1
1
70
120
175
0.325
25
0.450
1.3
0.185
1 1/4
1.25
70
120
180
0.300
20
0.175
1 1/2
1.5
70
120
182
0.300
15
0.180
2
2
70
120
185
0.325
10
0.195
Plasma
(H35)
Shield
(N
2
)
(Bar)
(Bar)
Volts
(mm)
±0.1
(mm/mi
n)
(mm)
(sec)
(mm)
4.8
8.3
157
6.2
2190
7.6
0.5
4.1
4.8
8.3
159
6.5
1790
7.6
0.6
4.3
4.8
8.3
164
7.3
1380
8.5
0.7
4.5
4.8
8.3
169
7.8
940
11.4
0.8
4.6
4.8
8.3
175
8.3
650
11.4
1.2
4.7
4.8
8.3
180
8.3
500
4.5
4.8
8.3
182
8.3
380
4.6
4.8
8.3
185
8.3
260
4.9
* Lock pierce height between 0.5" to 1" to avoid torch hitting the pierce metal puddle.
**Requires Firmware version 3.2 or higher on power supply and 2.0 or higher on Gas Control box.
Edge Start
38
Edge Start
50
Edge Start
15
20
25
32
Kerf Width
@ Rec.
Speed
(mm)
10
12
Edge Start
Edge Start
Edge Start
Material
Thickness
Cut Flow
Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height*
Pierce
Delay
200A Stainless Steel (H35/N
2
)
Material
Thickness
Cut Flow
Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height*
Pierce
Delay
Kerf Width
@ Rec.
Speed