SECTION TSM 142.2

ISSUE

E

PAGE 6 OF 14

DISaSSEMBlY

DaNgER !

Before opening any Viking pump liquid

chamber (pumping chamber, reservoir,

relief valve adjusting cap fitting, etc.)

Be sure:
1. That any pressure in the chamber has

been completely vented through the

suction or discharge lines or other

appropriate openings or connections.

2. That the driving means (motor,

turbine, engine, etc.) has been “locked

out” or made non-operational so that

it cannot be started while work is

being done on pump.

3. That you know what liquid the

pump has been handling and the

precautions necessary to safely

handle the liquid. Obtain a material

safety data sheet (MSDS) for the

liquid to be sure these precautions

are understood.

Failure to follow above listed

precautionary measures may result in

serious injury or death.

1. Mark head and casing before disassembly to make sure

they are reassembled properly. Remove the head from

the pump.
CAUTION: DO NOT ALLOW THE IDLER TO FALL

FROM THE IDLER PIN.
Tilting the top of the head back as it is removed will

prevent this occurrence. Avoid damaging the head gasket

if possible. If pump is furnished with a relief valve, it need

not be removed from head or disassembled at this point.

Refer to “Pressure Relief Valve Instructions”, page

13. If the pump has a jacket head plate, this plate will

separate from the head when the head is removed from

the pump. The gasket for jacket head plate between

the head and the jacket head plate should be removed

and the gasket surfaces on the above parts cleaned.

Disassembly will probably require replacement of the

gasket for jacket head plate between the pump head and

jacket head plate.

These gaskets should be carried as spare parts for

pumps thus equipped.

2. Remove the idler and bushing assembly.
3. Bend up tang of lockwasher and with a spanner wrench

remove the locknut and lockwasher from the shaft.

NOTE: A piece of hardwood or brass inserted in casing

port and between rotor teeth will prevent the shaft from

turning.

4. Remove the packing gland nuts.

gREaSE FITTINg lOCaTION

INNER SPaCER COllaR

OUTER SPaCER COllaR

lOCKWaSHER

SETSCREWS

OUTER END CaP

lOCKNUT

INNER lIP SEal

HalF ROUND RINgS

INNER END CaP

NYlON INSERT

SHaFT

Ball BEaRINg

BRaCKET

OUTER lIP SEal

FIgURE 4