Viking Pump TSM710.1: HLE-ALE 4076/4176 User Manual

Page 5

Advertising
background image

iTeM

NAMe Of PArT

iTeM

NAMe Of PArT

iTeM

NAMe Of PArT

1

Locknut

13

Flush Line Assembly

25

Rotor and Shaft Assembly

2

Bearing Spacer Collar (2-Req’d)

14

Pipe Plug

26

Idler and Bushing Assembly

3

End Cap

15

Casing and Bushing Assembly

27

Idler Bushing

4

Lip Seal (2-Req’d)

16

Relief Valve Assembly

28

O-Ring For Head

5

Ball Bearing

17

Dowel Pin (2-Req’d - 4176 Series Only)

29

Idler Pin

6

Setscrew (2-Req’d)

18

Foot (4176 Series Only)

30

Head and Lube Idler Pin Assembly

7

Bearing Housing

19

Lockwashers for Foot (4176 Series Only)

31

Pipe Plug, Hex Head, 1/8” BSP (ALE & ATE)

8

Setscrew (2-Req’d)

20

Capscrews for Foot (4176 Series Only)

32

O-Ring For Jacketed Head Plate (Optional)

9

Nylon Insert (2-Req’d)

21

Relief Valve Gasket (2-Req’d on ATE & ALE)

33

Jacketed Head Plate (Optional)

10

O-Ring For Seal Seat

22

Casing Bushing

34

Head Capscrews

11

Mechanical Seal

23

Cover Plate (Pumps Less Valve 2-Req’d on ATE & ALE)

Not illus.

Pipe Flange Gasket (2-Req’d)

12

Grease Fitting

24

Capscrews for Relief Valve or Cover Plate

SECTION TSM 710.1

ISSUE

C

PAGE 5 OF 8

1

2

3

4

5

2

4

6

7

8

9

10

11

12

13

14 16

17

18

19

20

25

26

27

28

29 30

31

21

22

24

23

16

24

23

21

33

32

34

15

HLE RELIEF VALVE ONLY

figure 6

eXPLODeD vieW Of viKiNg SerieS 4076 / 4176 PuMPS

TAbLe 2

8. Install the lip seal in the end cap. See figure 4 for lip

orientation. Thread the end cap into the bearing housing

along with the outer bearing spacer collar. Tighten the

end cap. Lock the end cap in place with two radial

setscrews in the flange of the bearing housing.

9. See figure 7 and notes under “MeCHANiCAL

SeAL” on this page. Lubricate the outside diameter of

the seat gasket and install the stationary member of the

mechanical seal into the end of the bearing housing.

Note the shinny side of the seal seat faces out.

10. Slide the inner bearing spacer collar onto the shaft.

Thread the bearing housing assembly into the bracket.

11. Insert a length of hardwood or brass through either port

opening between the rotor teeth. This will keep the shaft

from turning when the lock nut is tightened. Install the

lock nut and tighten to 70-95 N•m on HLE pumps and

135-175 N•m on ATE and ALE pumps.

12. Adjust the pump end clearance as described in

“THruST beAriNg ADJuSTMeNT” on page 6.

13. Lubricate the grease fitting with multi-purpose grease,

NLGI #2.