Exide Technologies JA5009-00 User Manual
Page 2
SCR/SCRF Series Battery Charger
JF0026-00
Factory-Configured Specifications
MODEL No.
INPUT VOLTAGE
Vac
1
SERIAL No.
FLOAT VOLTAGE
Vdc
SMART PART No.
EQUALIZE VOLTAGE
Vdc
(items A-F req’d)
1
CORE (BB####)
A B C D
E
F G
H
J
K
L M N
1 - Serial Number and Core (BB####) calculated by factory
Pos.
SMART
PART
CODE
DWG#
DESCRIPTION
(X)
DWG#
DESCRIPTION
U
UNFILTERED DC OUTPUT
EJ0088
GROUND DETECTION INDICATOR LIGHTS
F
FILTERED DC OUTPUT
(30 mV RMS w/BATTERY)
EJ0095
2% ACCURACY 3.5in AC VOLTMETER (1PH)
A
E
BATTERY ELIMINATOR DC OUTPUT FILTERING
EJ0120
BATTERY DISCHARGE ALARM & IND. LIGHT
1
120 Vac - 60 Hz INPUT
(SINGLE PHASE ONLY)
EJ0121
2% ACCURACY 3.5in AC VOLTMETER (3PH)
2
208/240 Vac - 60 Hz INPUT
EJ0123
COMMON ALARM BUZZER
3
220/240 Vac - 50/60 Hz INPUT (SINGLE PHASE ONLY)
EJ0134
2% ACCURACY 3.5in AC AMMETER (1PH)
4
380/416 Vac - 50/60 Hz INPUT
(THREE PHASE ONLY)
EJ0135
2% ACCURACY 3.5in AC AMMETER (3PH)
5
480 Vac - 60 Hz INPUT
EJ0137
CURRENT LIMIT ALARM & IND. LIGHT (1PH / 3PH)
6
120/208/240 Vac - 60 Hz INPUT (SINGLE PHASE ONLY)
EJ0138
0-CENTER DC AMMETER FOR BATT/LOAD MONITOR
7
208/240/480 Vac - 60 Hz INPUT
EJ0143
END OF DISCHARGE ALARM & INDICATOR LIGHT
B
0
Vac
Hz INPUT
(CUSTOM)
EJ0145
CABINET HEATER STRIPS
F
REDUNDANT DC FUSE PROTECTION
(F1 / F2)
EJ0155
HIGH-LOW AC VOLTAGE ALARM & INDICATOR
LIGHTS
B
STANDARD DC CIRCUIT BREAKER
(F1 / CB2)
EJ0439
OVER-TEMPERATURE ALARM w/ (BUZZER / IND.)
C
C
CUSTOM DC PROTECTION
EJ0615
DC POWER ON INDICATOR LIGHT
1
EJ0450
MANUAL FLOAT / EQUALIZE SWITCH
EJ082X
INTERNAL TEMPERATURE COMPENSATION (PB/NICD)
2
EJ0093
MANUAL FLOAT / EQUALIZE SWITCH & IND. LIGHTS
EJ1123
4-20 mA TRANSDUCER
Adc
Vdc
3
EJ0097
0-72 HR. MANUAL EQUALIZE TIMER
EJ1165
HIGH AC RIPPLE ALARM w/ INDICATOR LIGHT
4
EJ0869
MAN. EQUALIZE TIMER w/ F/E SWITCH & IND. LIGHTS
EJ1234
AC INPUT LIGHTNING ARRESTOR (1PH / 3PH)
5
EJ0131
AC FAILURE AUTO-EQUALIZE TIMER & IND. LIGHTS
EJ1247
VENT FAN CONTROL RELAY & IND. (FROM EQUALIZE)
6
EJ0096
0-72 HR. MANUAL EQUALIZE TIMER & IND. LIGHTS
EJ1303
BATTERY OPEN ALARM & IND LIGHT
D
0
CUSTOM EQUALIZATION
EJ1398
EXTERNAL TEMP COMPENSATION PROBE (PB/NICD)
2%
2% ACCURACY 3.5in ANALOG DC METERS
EJ5005
0-72 HR. MAN. EQ. TIMER & IND. w/ REMOTE EQ.
1%
1% ACCURACY 3.5in ANALOG DC METERS
EJ5012
0-999 HR. MAN. EQUALIZE TIMER w/ SW & IND.
LIGHTS
SB
1% ACCURACY 4.5in SWITCHBOARD DC METERS
EJ5087
AUXILIARY CONTACTS (TB15-AUX) ON CASM (EJ0837)
DM
EJ0895
0.1% ACCURACY 3.5in LED DIGITAL DC METERS
SURGE WITHSTAND FILTER (SWC) PER IEEE-472
E
CM
CUSTOM DC METERS
kAIC AC
kAIC DC CIRCUIT BREAKERS
P
STANDARD (COLOR-CODED PVC) WIRING
200 kAIC AC FUSING
(1PH - 2-POLE / 3PH - 3-POLE)
F
H
CB0002
SWITCHBOARD INSULATION SYS. (#-CODED) WIRING
AC
DC
CKT BKR AUX CONTACTS
A
EJ0085
AC POWER FAILURE ALARM & INDICATOR LIGHTS
COPPER GROUND BUS BAR
w/ LUG(S)
G
C
CUSTOM AC FAILURE ALARM
FUNGUS PROOFING PER CA0004-00
C1
EJ0837
CASM PC BOARD w/ ONE (1) FORM-C CONTACTS
SPECIAL NEMA
CABINET TYPE
C2
EJ0837
CASM PC BOARD w/ TWO (2) FORM-C CONTACTS
in RELAY RACK MOUNTING ASSY.
HL
EJ0083
HIGH / LOW DC VOLTAGE ALARM & IND. LIGHTS
SPECIAL (FLOOR / WALL) MOUNTING ASSY.
ZC
EJ0127
CHARGER FAILURE ALARM (NO Adc) & IND. LIGHTS
CUSTOM TAG PLATE
H
HZ
HLVA / CFA & IND. LIGHTS (EJ0083 & EJ0127)
ENGRAVED FUNCTIONAL NAMEPLATES
S
EJ0094
GND. DET. SWITCH FOR DC VOLTMETER INDICATION
EJ5007 -00
WHITE CHARACTERS ON BLACK BACKGROUND
L
EJ0089
GND. DET. IND. LIGHTS w/ GROUND & LAMP TEST
EJ5007 -10
BLACK CHARACTERS ON WHITE BACKGROUND
J
R
EJ0086
GND. DET. RELAYS w/ RESET SWITCH & IND. LIGHTS
X
JH0002 -09 PARTS DATA PACKAGE PER MFG. SWITCHBOARD
K
F
EJ0133
PARALLEL CHGR OPERATION w/ 2% LOAD SHARING
X
JH0002 -07 COPY OF TEST DATA PER NEMA PE5-1985
L
H
EJ0592
HIGH DC VOLTAGE CHARGER SHUTDOWN
EXTRA INSTRUCTION MANUALS
R
EJ0141
COMMON ALARM RELAY CONTACTS
JH0003
CUSTOM DRAWING PACKAGE
CAD DISK
B
EJ0141
COMMON ALARM RELAY CONTACTS w/ BUZZER
JH0002 -06 CERTIFIED TEST DATA PER NEMA PE5-1985
M
C
EJ0967
COMMON ALARM BUZZER FOR CASM PC BOARD
JH0002 -03 CERTIFICATE OF CONFORMANCE
D
EI5030/31 DRIP SHIELDS - STYLE-1A/1B CABINET (EB0220/221)
JH0002 -01 BURN-IN OR HEAT-RUN
HOURS
D
EI5032
DRIP SHIELDS - STYLE-2 CABINET (EB0222)
JH0002 -00 IN-HOUSE INSPECTION BY OUTSIDE PERSONNEL
D
EI5033
DRIP SHIELDS - STYLE-3 CABINET (EB0123)
JH0004 -01 EXPORT PACKING PER FS0001-00
D
EI5034
DRIP SHIELDS - STYLE-4 CABINET (EB0163)
JH0004 -05 CUSTOM PACKING
N
D
EI5035
DRIP SHIELDS - STYLE-5 CABINET (EB0198)
JH0004 -10 EXTENDED WARRANTY PER JF5001-00
GENERAL SPECIFICATIONS:
ADDITIONAL FEATURES / OPTIONS / NOTES:
Regulation:
+ or - 0.5%
no-load to full-load
Regulation:
+ or - 0.5%
for + or - 10% AC line variation
Regulation:
+ or - 1%
for combined load, line & temp. variations
Ambient Temperature Range:
0º C to 50º C
Relative Humidity:
up to 95% without condensation
Altitude:
up to 1,000m above sea level