PRESET - Preset Execution/Reporting
This command selects/reports the state of a preset.
Command form: DEVICE PRESET <Channel> [Value]
Argument details
Name
Description
Units
Device
0—7 or * to select all units
PRESET
Command
Channel
1—32 (select preset)
Value
0 =Set the preset state to off
1 = Execute the preset and set the state to on
2 = Execute the preset and set the state to off
Null = Returns the current preset state
Example:
#72 PRESET 5 1 On XAP 400 unit 2 (#72), preset (PRESET) 5
will execute and set the state to on (1).
PRGSTRING - Program String
This command sets/reports a programmed string.
Command form: DEVICE PRGSTRING <ID> [Value]
Argument details
Name
Description
Device
0—7 or * to select all units
PRGSTRING
Command
ID
0 — 7 (string location)
Value
1—80 Characters
CLEAR = Clear current value
Null = Current value
Example:
#73 PRGSTRING 2 MUTE On XAP 400 unit 3 (#73), string
location 2 is programmed (PRGSTRING) with MUTE.
Supported special characters
\a = alert
\b = backspace
\f = formfeed
\n = new line
\r = carriage return
\t = horizontal tab
\v = vertical tab
\\ = backslash