PRESET - Preset Execution/Reporting

This command selects/reports the state of a preset.

Command form: DEVICE PRESET <Channel> [Value]

Argument details

Name

Description

Units

Device

0—7 or * to select all units

PRESET

Command

Channel

1—32 (select preset)

Value

0 =Set the preset state to off
1 = Execute the preset and set the state to on
2 = Execute the preset and set the state to off
Null = Returns the current preset state

Example:

#72 PRESET 5 1 On XAP 400 unit 2 (#72), preset (PRESET) 5

will execute and set the state to on (1).

PRGSTRING - Program String

This command sets/reports a programmed string.
Command form: DEVICE PRGSTRING <ID> [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

PRGSTRING

Command

ID

0 — 7 (string location)

Value

1—80 Characters
CLEAR = Clear current value
Null = Current value

Example:

#73 PRGSTRING 2 MUTE On XAP 400 unit 3 (#73), string

location 2 is programmed (PRGSTRING) with MUTE.

Supported special characters

\a = alert
\b = backspace
\f = formfeed
\n = new line
\r = carriage return
\t = horizontal tab
\v = vertical tab
\\ = backslash