Sequence of opera tion – Louisville Tin and Stove BBT104 User Manual

Page 15

Advertising
background image

SEQUENCE OF OPERA

TION

STEP #

1

)

Thermostat calls for heat.

2

)

Inducer turns on.

3

)

Pressure switch closes.

4

)

Power to ignitor

.

5

)

Gas flow to burner

.

6

)

Burner ignition proven.

NOTE: If there is a malfunction in any of the above steps, the sequence will stop at

that

point

and return to Step 2. If after 3 attempts malfunction still occurs, control will go into lockout

mode for one hour

. This one hour lockout can be bypassed by resetting the thermostat, or

interrupting power

.

7

)

Thermostat satisfied.

8

)

Gas valve closes.

9

)

Inducer turns off.

HEA

TER IS NOW IN ST

ANDBY MODE.

Page 15

Thermostat

calls for heat

Power to Draft

Inducer

(V

entor Motor)

Pressure

Switch Closes

(Fan Proved)

Spark Ignition

Energized

Gas control

valve opens gas

flow to burner

Ignition

Proved

Heating

Cycle

Thermostat

satisfied

Gas control

valve closes

Draft

inducer off

Stand-by

mode

в

в

в

в

в

в

в

в

в

в

в

в

Lockout

after 3

attempts

NO

NO

20 Sec.

Post Purge

15 Sec.

Advertising