4 parameter list and ranges – Dynalco SWTD-1000 Speed Switch/Transmitter User Manual

Page 15

Advertising
background image

Operating Instructions SWTD-1000

DYNALCO

13

//

8.4 Parameter List and Ranges

If you already have a configuration file you can open and view it using the SWTD-1000 Windows
Software menu
File

Æ Open

You can also connect the SWTD-1000 to a PC (see section 8.2) and read back the parameters,
SWTD-1000

Æ Read parameters


Once loaded into the software the parameter set may be printed via File

Æ Print


Normal Windows file handling rules apply.

Parameter list and ranges. Factory settings are shown in bold.



Configuration < System >

Machine factor

1.0000E-07 ... 1.0000 ... 9.9999E+07

Minimum Measuring time

2 / 5 / 10 / 20 / 50/ 100 / 200 / 500 ms / 1/ 2 / 5 Seconds

Min displayed measured value

1.0000E-12 ... 1 ... 1.0000E+12

Alarm definition

Only System error System error OR Sensor Monitoring


Configuration < Sensor >

Sensor Type

Active / Passive

Sensor input

Analog (Sign) / Digital (IQ)

Sensor current minimum

0.5 ... 1.5 ... 25.0mA

Sensor current maximum

0.5 ... 25.0mA


Configuration < Analog output >

Measuring range start value

0.0000 ... 90% of the end value

Measuring range end value

1Hz … 2000.0 500000

Output range

0 ... 20mA / 4 ... 20mA

Time constant (Damping)

0.0 ... 9.9s


Configuration < Limits >

Status Limit

1

On / Off

Status Limit

2

On / Off

Mode Limit

1

Normal / Inverse

Mode Limit

2

Normal / Inverse

Lower Set point

Limit 1

0.1 … 200.00 … 500000

Upper Set point

Limit 1

0.1 … 300.00 … 500000

Lower Set point

Limit 2

0.1 … 400.00 … 500000

Upper Set point

Limit 2

0.1 … 500.00 … 500000


Configuration < Relay control >

Switching of control A/B

Selection of actuator

None (always control A) / Binary Input B1

Delay time

0 ... 2.000 s

Relay Assignment

Control

A

Alarm / Sensor monitor / Limit 1 / Limit 2 / Window / On / Off

Acknowledge A

Without acknowledge (no hold function) /
Relay held when control active /
Relay held when control inactive

Acknowldge

B

Alarm / Sensor monitor / Limit 1 / Limit 2 / Window / On / Off

Acknowldge

B

Without acknowledge (no hold function) /
Relay held when control active /
Relay held when control inactive