Table 5-7, Table 5-8, Location – Cisco SFS 7008 User Manual
Page 72: Interpreting the management interface leds
72
Location
The Management Interface modules are located at the top of back the chassis. Refer to
Figure 5-5
to
view the chassis diagram.
Figure 5-6: Management Interface Module LEDs
Interpreting the Management Interface LEDs
System Status LEDs
Management Interface Status LEDs
Table 5-7: Interpreting the Management Interface Module System Status LEDs (see
)
Color
State
Indication
Green and Yellow
off
No module power, or LED failure.
Green
solid on
System running with no errors detected.
Green
off
No power to the Management Interface module, LED failure,
or yellow LED is ON.
Yellow
solid on
At least one module failure in the system. Operator attention
required.
The “!” label indicates a failure.
Yellow
blinking
Identify. Assists in identifying a particular Field Replaceable
Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the diag LED test.
Refer to the Command Line Reference Guide for more
information.
Example:
Run the identity test on Power Supply 1:
config mode -> diag card 15 ->
test led ->
-> start - start flashing
-> stop - stop flashing
Table 5-8: Interpreting the Management Interface Module Status LEDs (see
)
Color
State
Indication
Green over Yellow
off
No module power, or LED failure.
Green
solid on
The Management Interface module is running with no errors
detected.