V40 EB/EH and LBM Troubleshooting Tips for Default Setting
No LED activity when key is
turned CCW to armed position
When the unit is armed, red LED
flashes twice, green LED is on
for 15 seconds, but the unit does
give three beeps after the green
LED goes off. The unit will not
sound when opened.
LED's do not flash to indicate
armed or disarmed status
Give low battery alert.
When the unit is armed, red LED
flashes twice, green LED is on
for 15 seconds, but the unit does
give three beeps after the green
LED goes off. The unit will not
sound when opened.
Battery connector missing
Dead or weak battery.
Battery not secured to connector
correctly.
Slide switches not in default mode.
Outside trim not correctly installed.
Actuator is sticking to microswitch
Status indication switch is in off
position.
Dead or weak battery.
Dead latch not in proper position.
1/4-20 screws not installed.
L9 option ordered
Install new battery, LED's should flash and the
siren beep once.
Secure battery correctly.
Set switch to defalut and reconnect power.
Check outside trim (if applicable). See trim
instructions.
Lubricate spring
Remove battery power from unit. Slide status
indicator switch to the ON position.
Reinstall battery.
Install new battery, LED's should flash and the siren
beep once.
Close door.
Door not fully closed. Press dead latch manually as
shown in Fig 2 on pg 13.
If unit operates properly, check unit's backset and
adjust unit or add shims to strike as needed.
See page 5, bubble #2.
Battery connector not supplied with L9 option
EB/EH (Bar Monitoring)
PROBLEMS
PROBABLE CAUSE
ACTION
Technical Support 1-800-729-3839
LBM (Latchbolt Monitoring)
PROBLEMS
PROBABLE CAUSE
ACTION
101275 Page 14