2.1 Output[x] [Name] LPF
->

Y

F = 20.0 Hz

2.1a.

If selected a filter from

Buttw_1st

up to Bessel_4th, then

the filter's Cutting Frequency can be set as follow:

Output[x] [Name] LPF

[Thousands Editor]

[Hundreds Editor] [Units Editor]

-> Edit Freq = 250Hz

[Freq.] 1000Hz

[Freq.] 100Hz

[Freq.] 1Hz

:

:

:

20000Hz

900Hz

100Hz

2.1b.

If selected a

Custom Filter

(from 2

nd

up to 4

th

order), depending

from the filter's order, the cascade of second order Cells building
the filter are available for editing in their Freq and Q parameter,
independently.
For proceeding with the editing of a custom filter Cell, the Param.1 is
here used for the Cell selection.
So, a Custom Filter can be set in its parameters, as follow:

2.1b.1.

If selected a

Custom_2nd

filter

Output[x] [Name] LPF
->Custom_2nd F = 250Hz

[2

nd

order Cells selection]

Filt

x

F= 250Hz Q = 0.3

[2

nd

Ord Cell

x

] x=1

[Freq.] 20Hz

[Q] 0.05

:

:

:

x=1

20kHz

10.00

2.1b.2.

If selected a

Custom_3rd

filter

Output[x] [Name] LPF
->Custom_3rd F = 250Hz

Filt

x

F= 250Hz Q = 0.3

[2

nd

Ord Cell

x

] x=1

[Freq.] 20Hz

[Q] 0.05

:

:

:

[Q not available] x=2

20kHz

10.00

2.1b.3.

If selected a

Custom_4th

filter

Output[x] [Name] LPF
->Custom_4th F = 250Hz

Filt

x

F= 250Hz Q = 0.3

[2

nd

Ord Cell

x

] x=1

[Freq.] 20Hz

[Q] 0.05

:

:

:

x=2

20kHz

10.00

Once editing the Cells “Filtx”, pressing the Enter Button can be accessed also for the Custom Filters the page for the fast frequency setting, as available for the NOT Custom
Filters and which way of working is described at the point 1.1a.

3. Out-[x]

EQ-[x] (X from 1 to 5)

Byp = Off Type = Y (Y = Peaking_Eq, Hi-Shelv_1, Hi-Shelv_2, Hi-Shelv_Q, Lo-Shelv_1, Lo-Shelv_2, Lo-Shelv_Q,

Lo-Pass_1, Lo-Pass_2, Lo-Pass_Q, Hi-Pass_1, Hi-Pass_2, Hi-Pass_Q, All Pass_1, All Pass_2,
Band Pass, Notch Filt)

-> Byp = Off Type = Y

Param.1 N/A

Off

Peaking_Eq

:

:

On

Notch Filt

Through the Param.2, it is possible to Byp the single selected filter.
Through the Param.3, it is possible to select one of the 17 available
filters' type.
Once selected the filter Type and NOT in Byp mode, pressing
again the ENTER button can be accessed the selected filter's editing page.

3.1 Out-[x]

EQ-[x] (X from 1 to 5)

-> Byp = Off Type =

Y

3.1a.

If selected a

Peaking_Eq

filter, then the filter can be set by

the following parameters

Out-[x]

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q=1.00

[Freq.] 20Hz

[Amp.] -15.0 dB

[Q] 0.30

:

:

:

20kHz

+15.0 dB

20.00

3.1b.

If selected a

Hi-Shelv_1

(first order High Shelving) filter,

then the filter can be set by the following parameters

Out-[x]

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q= ----

[Freq.] 20Hz

[Amp.] -15.0 dB

[Q] ----

:

:

:

20kHz

+15.0 dB

----

3.1c.

If selected a

Hi-Shelv_2

(second order High Shelving) filter,

then the filter can be set by the following parameters

Out-[x]

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q= ----

[Freq.] 20Hz

[Amp.] -15.0 dB

[Q] ----

:

:

:

20kHz

+15.0 dB

----

3.1d.

If selected a

Hi-Shelv_Q

(variable Q High Shelving) filter,

then the filter can be set by the following parameters

Out-[x]

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q=1.00

[Freq.] 20Hz

[Amp.] -15.0 dB

[Q] 0.30

:

:

:

20kHz

+15.0 dB

20.00