Table 3-66, Table 3-67 – Kontron COMe-cP2020 User Manual
Page 69

www.kontron.com
COMe-P2020 User Guide
69
Table 3-66:
0x376: Board Interrupt Pending Register 1
ACTION
D7
D6
D5
D4
D3
D2
D1
D0
READ
0
0
0
Int4
Int3
Int2
Int1
Int0
WRITE
NU
NU
NU
w1c
w1c
w1c
w1c
w1c
POWER UP
0
0
0
0
0
0
0
0
BITFIELD
DESCRIPTION
[D0]
Int0
Interrupt occurred, triggered by CON_IRQ[1]# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active
[D1]
Int1
Interrupt occurred, triggered by CON_IRQ[2]# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active
[D2]
Int2
Interrupt occurred, triggered by CON_IRQ[3]# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active
[D3]
Int3
Interrupt occurred, triggered by CON_IRQ[4]# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active
[D4
Int4
Interrupt occurred, triggered by CON_IRQ[5]# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active
Table 3-67:
0x377: Board Interrupt Pending Register 2
ACTION
D7
D6
D5
D4
D3
D2
D1
D0
READ
Int7
Int6
Int5
Int4
Int3
Int2
Int1
Int0
WRITE
w1c
w1c
w1c
w1c
w1c
w1c
w1c
w1c
POWER UP
0
0
0
0
0
0
0
0
BITFIELD
DESCRIPTION
[D0]
Int0
Interrupt occurred, triggered by CON_SMB_ALERT# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active
[D1]
Int1
Interrupt occurred, triggered by LM73_TEMP_ALERT# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active
[D2]
Int2
Interrupt occurred, triggered by CON_THERM# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active
[D3]
Int3
Interrupt occurred, triggered by CON_PWR_OK line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active
[D4]
Int4
Interrupt occurred, triggered by CON_BATLOW# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active
[D5]
Int5
Interrupt occurred, triggered by RTC_INT# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active
[D6]
Init6
Interrupt occurred, triggered by CON_WAKE0# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active
[D7]
Init7
Interrupt occurred, triggered by CON_WAKE1# line. Register is cleared by write to '1':
'0' = no Interrupt