Miller DS20 User Manual

Page 4

Advertising
background image

4

Before using please read the following operating instructions.

Do not omit any step. N.B. The safe operation of this piece of

professional equipment is the responsibility of the operator.

1.1 Loosen the PAN HANDLE CLAMP fully, then rotate the

PAN HANDLE until it is approximately perpendicular to the

THREADED STUD and tighten the PAN HANDLE CLAMP

- avoid contact wear between the serrations on the Fluid

Head and the PAN HANDLE CLAMP, if this occurs then

unwind the PAN HANDLE CLAMP further.

1.2 Ensure that the TRIPOD BOWL is approximately horizontal.

Place the Fluid Head into the TRIPOD BOWL, adjust the

BUBBLE LEVEL such that the bubble is inside the black

circle and tighten the CLAMP NUT.

Note:

If adjusting the level with your camera mounted, first

ensure the camera is securely held before loosening CLAMP NUT.

Please note that the best camera control can be achieved by

balancing camera centre of gravity (C of G) over centre axis

of the head, and by selecting the appropriate counterbalance

position to suit the weight of the camcorder payload.
The DS5/DS10/DS20 is equipped with a sliding camera plate and

a removable 1/4”-pin carriage which is standard mounting for

DV and MiniDV camcorders. The DS20 is also fitted with a 3/8” &

1/4” screws which is standard mounting for DVCAM (see Fig1.3).

The 3/8” & 1/4” screws also allow the DS20 to attach to a

proprietary Quick Release Tripod Adaptor or “tripod base plate”

such as the Sony VCT-14 or Panasonic SHAN-TM700.
2.1 Lock PAN and TILT LOCKS (rotate both levers clockwise until

firm).

2.2 Remove CAMERA PLATE from CAMERA PLATFORM by

unlocking the SLIDE LOCK, pushing SAFETY TAB and sliding

the CAMERA PLATE rearward

2.3 With accessories and battery fitted to the camera, it is

recommended to estimate the camera’s Centre of Gravity (C

of G) for the purpose of correctly positioning the camera on

the CAMERA PLATE. The camera’s C of G can be estimated

by placing the camera on to a round rod and then shifting

it backwards or forwards until a balance point – C of G - is

achieved. It is recommended to identify this point as it will be

useful in step 2.5.

2.4 Refer to the Camera’s owners manual for correct method of

attachment to the CAMERA PLATE. Attach the camera or the

Quick Release Tripod Adaptor to the CAMERA PLATE and

securely tighten the screws.

2.5 Check that the SLIDE LOCK is loose, then align the

CAMERA PLATE with the CAMERA PLATFORM and

slide it forward until the safety mechanism is engaged.

Then, slide the CAMERA PLATE so that the camera’s C of G

is directly above the centre axis of the Fluid Head and tighten

the SLIDE LOCK. If this can not be achieved then reposition

the camera or the Quick Release Tripod Adaptor on the

SLIDING PLATE – step 2.4. This will ensure that the system

has maximum stability.

2. Camera Set-up

Operating Instructions

1. Fluid Head Set-up

Advertising
This manual is related to the following products: