12. Installing the Resting ECG Module

Before you can start recording ECGs, you need to

Install the hardware

Install the correct drivers (when you use a CPCOM card or USB Unilink)

Configure the software


The installation procedures of the CPCOM cards depend on the operating system of your
computer. Therefore, all sets of instructions include explanations for each operating system.

12.1. Connecting the RS232 interface

(Unilink for Portable- or MD- or Prolink for Pro recorder)


The RS232 Interface can be used with all versions of MS Windows. To use a RS232 Interface,
you need a free serial port on your computer.

To set up your computer for use of the RS232 Interface:

1. Connect the RS232 Interface to one of the serial ports of the computer.

2. If a Pro-recorder is used, connect the other end of the interface directly to the

recorder.

If a Portable or MD recorder is used, insert one end of the optical fiber into the optical output
receptacle at the back of the recorder and insert the other end into the respectable on the
interface.

After you have connected the Interface you need to configure Welch Allyn CardioPerfect
Workstation so that it uses the correct port.

To configure Welch Allyn CardioPerfect Workstation:

1. Start Welch Allyn CardioPerfect Workstation and log in as Administrator.

2. In the File menu, click Settings, click ECG, and click on the Recorder tab.

3. From the Port list, select the COM port to which the Interface is connected. Most often

this is either COM1 or COM2.

12.2. Connecting the USB interface

(Unilink for Portable- or MD- or Prolink for Pro-recorder)


The USB Interface cannot be used with MS Windows 95 or MS Windows NT4. To use an USB
Interface, you need a free USB port on your computer.
On the Installer menu of the Welch Allyn CardioPerfect Workstation you will find an item called
“Install Unilink USB / CardioPerfect Pro Drivers.”
Please run this install prior to inserting the USB-Interface into a USB socket of your
computer.
The installation wizard will prompt you to select whether the USB-Unilink drivers or the
Prolink-USB drivers should be installed

To set up your computer for use of the USB Interface:

1. Connect the USB Interface to the USB port of the computer.

2. If a Pro-recorder is used, connect the other end of the interface directly to the