Wine Guardian Ducted Wine Cellar Cooling Systems (WG175) - Manual User Manual
Page 6

2
格栅或扩散片 -空气进口或出口引导板,或机器的保护板。
Heat Gain / Loss – The amount of cooling or heating expressed in watts transferred between the
wine cellar and the ambient space. The Wine Guardian must offset this load.
热增益/损失 - 酒窖和环境空间的冷却或加热的总额用瓦表示。酒卫主机机组必须抵消这种负
荷。
Inlet Air – The air entering the evaporator and condenser sections of the Wine Guardian
unit. NEC– National Electrical Code
进气 - 空气进入机组的蒸发器和冷凝器部分。 NEC 公司,美国国家电气规程
Recovery – The amount of cooling the unit does to return the cellar to its set point temperature after
some new load is introduced, such as people or new cases of warm wine entering the cellar.
恢复
– 增加新的负载后,如进人或暖酒进窖,主机恢复酒窖设定温度所需的制冷量。
Return Air - The air leaving the cellar and returning to the inlet of the evaporator coil.
回风 - 空气离开地窖并返回到蒸发器盘管的入口。
SP – Static pressure. Unit of measurement (mm of water or pascals of water column) of the pressure of
the air handled by the fan.
警司 - 静态压力。计量单位(水或水柱帕斯卡毫米)的风扇所处理的空气压力。
S
et Point – The desired temperature or humidity set on the thermostat or
humidistat.设置点 –在恒温或恒湿设置 所需的温度或湿度。
Supply Air - The air entering the cellar from the discharge of the evaporator
coil.
供应空气 - 空气通过蒸发器线圈进入酒窖。