Temperature and humidity – Wine-Mate SSLWC Series User Manual

Page 7

Advertising
background image

- 6 -

Temperature and Humidity

1. The controller

Fig. 2 TEMPERATURE CONTROLLER

1) Keys

SET: To display set-point; in programming mode it selects a parameter or
confirms an operation.

: To start a manual defrost.
: To see the maximum stored temperature; in programming mode it browses

the parameter codes or increases the displayed value.

: To see the minimum stored temperature; in programming mode it browses

the parameter codes or decreases the displayed value.

: To turn on/off the power to the unit.

+

: To lock/unlock the keypad.

SET+

: To enter in the programming mode.

SET+

: To return to the temperature display.


2) Lock and unlock the keys

To lock the keys, press up + down keys

+

until POF is displayed; to unlock

the keys, press up + down keys

+

until PON is displayed.


3) Display

During normal operating conditions, the display shows the value measured by
the air temperature probe. In case of active alarm, the temperature flashes
alternately to the code alarm. The LED functions are listed as follows.

LED MODE

FUNCTION

ON

Compressor enabled

Flashing

Anti-short cycle enabled

ON

Defrost cycle enabled

ON

Fan enabled

Flashing

Fan delay after defrost enabled

ON

Alarm occurring

ON

Temperature measuring unit

Flashing

Programming mode

Advertising