Beckett ADC 12Vdc User Manual

Page 8

Advertising
background image

8

Section: Burner Wiring

Figure 6A. Typical Wiring For Constant Duty Ignition - With No Primary Control

Figure 6B. Typical Wiring For Interrupted Ignition - With No Primary Control

30A

FUSE

IGNITER

10A

FUSE

SAFETY AND

LIMIT CONTROLS

OPERATING

CONTROLS

YELLOW
CAPPED

(NOT USED)

SOLID

WHITE

50A

FUSE

VALVE

VIOLET(+)

WHITE(-)

BLACK

ORANGE

MOTOR

SK10087

FROM 12 - 13.5 Vdc

POWER SUPPLY

GND

BLUE WITH

WHITE STRIPE

BLACK

MOTOR

30A

FUSE

CAD

CELL

IGNITER

10A

FUSE

SAFETY AND

LIMIT CONTROLS

OPERATING

CONTROLS

ORANGE

BLACK

WHITE(-)

VIOLET(+)

VALVE

BLACK

SOLID
WHITE

50A

FUSE

BLUE W/
WHITE STRIPE

YELLOW

YELLOW

FROM 12 - 13.5 Vdc

POWER SUPPLY

GND

SK10088

Notes:
1. Wires are to be sized to prevent a voltage drop between battery and burner with burner running at full load.
2. Motor runs continuously in normal confi guration.
3. Hard-wire burner ground to battery. DO NOT USE CHASSIS GROUND SYSTEM.

Notes:
1. Wires aret to be sized to prevent a voltage drop between battery and burner with burner running at full load.
2. Hard-wire burner ground to battery. DO NOT USE CHASSIS GROUND SYSTEM.

Advertising