9145E NID Software User’s Manual
Network Performance
69
8. In the Version field, type the Test Distribution protocol version (1,2, 3 or 4) used when
distributing results and press Enter. Use the version numbers in Figure 4-25 to allow the
EMS system to receive the corresponding PM, CPM or SAM test result data.
Figure 4-24 Network Performance Distribution Connection Setup screen
Figure 4-25 Distribution Connection Versions
Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
9145E-101-1-0 V04.10 11:20:59
-------------NETWORK PERFORMANCE DISTRIBUTION CONNECTION SETUP-----------------
1) IP Address
2) State Disabled
3) Description
4) Retries 3
5) Timeout 5
6) Version 4
Enter a valid class A, B or C IP Address.