INSTALLATION

INSTALLATION

2. Remove end plate from heater: 6 Phillips screws fasten the

heater body end plate in place:

3. Remove 4 Phillips screws that hold connection box to heater:

4. Remove the 2 Phillips screws that fasten the electrical

connection box front face plate in place:

5. Slide the connection box front face plate out from the electrical

connection box:

6. Slide power cord retainer plate from electrical connection box

(top surface):

7. Loosen screws in terminal block to remove wires as required:

»

RED wires connect to Lamp #1 (closer to connection box)

»

BLUE wires connect to Lamp #2 (further end from box)

»

Do not disconnect power supply wires

»

Loosen the threaded clamping collar on the Liquid Tight

Connector located behind the wiring terminal

»

Pull wires out through the Liquid Tight Connector and top of

electrical connection box: