Adjusting the c-series voltage settings, Setting voltage parameters for charge control mode, Figure 2-9 – Windy Nation Xantrex C Series Multifunction DC Controller User Manual

Page 42: Bulk and float charge potentiometers (pots)

Advertising
background image

Installation

22

975-0004-01-02 Rev D

Adjusting the C-Series Voltage Settings

The charging voltage setpoints and voltage reconnect/
disconnect setting of the controller are adjustable using two
rotary potentiometer controls. The knobs are removable to
reduce the likelihood of accidental mis-adjustment if
bumped.

Calibrated scales, shown as scale marks, are provided to
allow setting of the control without requiring the use of a
digital voltmeter.

For more information regarding bulk and float charging
voltages, see

“Three-Stage Battery Charging” on page 4

.

Setting Voltage Parameters for Charge Control Mode

To set the controller to a specific voltage, point the setting
indicator at the scale mark representing the desired voltage.

The potentiometer scale for BULK charge voltage is
calibrated as follows:

12-volt system: 13.0 to 15.0 volts
in increments of 0.2 volts,

24-volt system: 26.0 to 30.0 volts
in increments of 0.4 volts,

48-volt system: 52.0 to 60.0 volts
in increments of 0.8 volts.

Figure 2-9 Bulk and Float Charge Potentiometers (pots)

Scale Marks

Potentiometers

Setting indicator

Advertising