Hydrualic Diagnosis

15

The Cylinder See Figure 3.7.

• Both ports of the cylinder are connected to the

control valve.

• When pressure is applied to the port at the base of

the cylinder (through the flexible high-pressure
hose), the ram extends.

• When pressure is applied to the shaft end of the

cylinder (through the trunnion), the ram retracts.

• When pressure is applied to one port, fluid from

the other port is forced back to the control valve by
the movement of the piston in the cylinder bore.

The Hoses:

The high pressure hoses:

High-pressure hoses connect the pump to the

control valve and the control valve to the base of
the cylinder.

• High pressure means 3,400 PSI (+ 100) working

pressure.

The low pressure hoses:

Low pressure hoses connect the tank to the pump

and the control valve to the tank.

• Hoses must not collapse under the suction pres-

sure to the pump.

• Low pressure hoses are fastened with hose

clamps.

NOTE: The low pressure hose that supplies the pump carries fluid under vacuum. If it leaks, it will draw-in air,

but may leak very little fluid out. This entrapped air will create cavitation in the pump. Poor pump perfor-
mance accompanied by whining or growling noises can indicate a leaky suction-side hose.

NOTE: The pressure of the fluid in the low pressure hose that runs from the control valve to the tank can be

approximately 300 PSI.

Figure 3.7

Cylinder

Figure 3.8

High pressure hose

Low pressure

hose