FA400
Frequency Agile
®
Receiver
Installation Instructions
02031D
Note
The FA400 is intended to be installed
by professional security technicians.
This receiver is intended for use with
indoor security systems. Use in out-
door applications may impair per-
formance.
DMP™ 1912XR and XR200 Interface
The FA400 can be interfaced with the
Digital Monitoring Products’ 1912XR
Command Processor Panel via the
DMP 872
HARD
-
WIRE
-
LESS
™ Interface
card and Loop Expander Harness.
The FA400 can be interfaced with the
DMP XR200 Command Processor
Panel via the DMP 472
HARD
-
WIRE
-
LESS
™ Interface card and Loop Ex-
pander Harness.
The FA400 can be mounted next to the
panel or at a distance of up to 500 per
receiver on 22 gauge wire. Install re-
ceivers away from large metal objects,
if possible. Mounting the receiver on
metal surfaces will impair performance.
Do NOT use shielded wire.
If two receivers are being used, set re-
ceiver jumpers to RCVR 1 position and
RCVR 2 positions, respectively. See
Figure 1. The receivers should be at
least 3 feet apart.
Vision Plus™ Installation
The FA400 can be mounted next to the
panel housing or at a distance not to ex-
ceed 1000 feet (combined wire run if two
receivers are connected to the system.)
Install receivers away from large metal ob-
jects. Mounting the receiver on metal sur-
faces will impair performance. Do NOT
use shielded wire.
The unit can be screw-mounted through
holes in corners of the housing base. See
Figure 1.
When only one FA400 is being used, con-
nect wires to panel as shown in Figure 1.
If two receivers are being used, set re-
ceiver jumpers to RCVR 1 position and
RCVR 2 positions, respectively. See Fig-
ure 1. The receivers should be at least 3
feet apart.
Figure 1: FA400
2
1
2 1
2 1
Receiver 1 position
Receiver 2 position
Receiver Jumper
Vs
GND OUT
White
Black
Red
Do NOT use without a jumper!
To connect the FA400 to the interface
card, wire-nut the ends of the receiver
cable to the
HARD
-
WIRE
-
LESS
™ Inter-
face card wire harness (red-to-red,
black-to-black, white -to-green (har-
ness). The harness yellow wire is not
used. Plug the harness connector into
the J4 connector.
Locating the FA400
Prior to installation, Inovonics recom-
mends use of the FA715 Survey Kit to
determine transmission characteristics
at the application site. The survey kit
helps determine optimal location of the
FA400 and FA-series transmitters.
Generally, it is advisable to place the re-
ceiver in a spot central to ALL transmit-
ters.
To solve range or transmission prob-
lems, installers may deploy FA575 High
Power Repeaters as needed.