Main specifications – KEYENCE XG-8000 Series User Manual
Page 9
9
XG-8000(P)/8002(P)/8500(P)/8502(P)/8700(P)/8702(P)
*1 For the type where a P is added to the end of the main unit, it will become a PNP Open Collector.
*2 Models equipped with the Ethernet port in the CPU unit support Ethernet port direct connection.
Main Specifications
Model type
XG-8700/8702
XG-8500/8502
XG-8000/8002
Pixels
• With CA-HX500C/HX500M connected
5 mega-pixel mode: 2432(H) x 2040(V),
approx. 4.96 mega-pixels
2 mega-pixel mode: 1600(H) x 1200(V),
approx. 1.92 mega-pixels
• With CA-HX200C/HX200M connected
2 mega-pixel mode: 1600(H) x 1200(V),
approx. 1.92 mega-pixels
• With CA-HX048C/HX048M connected
470 k pixel mode: 784(H) x 596(V), approx.
470,000 pixels
310 k pixel mode: 640(H) x 480(V), approx.
310,000 pixels
240 k pixel mode: 512(H) x 480(V), approx.
240,000 pixels
• With XG-H500C/H500M connected
5 mega-pixel mode: 2432(H) x 2050(V),
approx. 4.99 mega-pixels
• With XG-200C/S200C/H200C/200M/S200M/
H200M connected
2 mega-pixel mode: 1600(H) x 1200(V),
approx. 1.92 mega-pixels
1 mega-pixel mode: 1024(H) x 960(V),
approx. 980,000 pixels
• With XG-H100C/H100M connected
1000(H) x 1000(V), 1 mega-pixel
• With XG-035C/S035C/H035C/035M/S035M/
H035M connected
310 k pixel mode: 640(H) x 480(V), approx.
310,000 pixels
240 k pixel mode: 512(H) x 480(V), approx.
240,000 pixels
• With CA-HX200C/HX200M connected
2 mega-pixel mode: 1600(H) x 1200(V),
approx. 1.92 mega-pixels
• With CA-HX048C/HX048M connected
470 k pixel mode: 784(H) x 596(V), approx.
470,000 pixels
310 k pixel mode: 640(H) x 480(V), approx.
310,000 pixels
240 k pixel mode: 512(H) x 480(V), approx.
240,000 pixels
• With XG-200C/S200C/H200C/200M/S200M/
H200M connected
2 mega-pixel mode: 1600(H) x 1200(V),
approx. 1.92 mega-pixels
1 mega-pixel mode: 1024(H) x 960(V),
approx. 980,000 pixels
• With XG-H100C/H100M connected
1000(H) x 1000(V), 1 mega-pixel
• With XG-035C/S035C/H035C/035M/S035M/
H035M connected
310 k pixel mode: 640(H) x 480(V), approx.
310,000 pixels
240 k pixel mode: 512(H) x 480(V), approx.
240,000 pixels
• With CA-HX048C/HX048M connected
470 k pixel mode: 784(H) x 596(V), approx.
470,000 pixels
310 k pixel mode: 640(H) x 480(V), approx.
310,000 pixels
240 k pixel mode: 512(H) x 480(V), approx.
240,000 pixels
• With XG-035C/S035C/H035C/035M/S035M/
H035M connected
310 k pixel mode: 640(H) x 480(V), approx.
310,000 pixels
240 k pixel mode: 512(H) x 480(V), approx.
240,000 pixels
Camera input
Two color/monochrome cameras (Compatible
with CA-HX500C/HX500M/HX200C/HX200M/
HX048C/HX048M and XG-H500C/200C/
S200C/H200C/H100C/035C/S035C/H035C/
H500M/200M/S200M/H200M/H100M/035M/
S035M/H035M, mixed connection possible)
Two color/monochrome cameras (Compatible
with CA-HX200C/HX200M/HX048C/HX048M
and XG-200C/S200C/H200C/H100C/035C/
S035C/H035C/200M/S200M/H200M/H100M/
035M/S035M/H035M, mixed connection
possible)
Two color/monochrome cameras (CA-HX048C/
HX048M and XG-035C/S035C/H035C/035M/
S035M/H035M can be connected.Mixed
connection is possible.)
By using expansion unit CA-E800/XG-E800, up to four cameras can be connected (mixed connection is possible).
When the CA-EC80/XG-EC80 is equipped: Two cameras per expansion unit
When the CA-EC80HX/CA-EC80L/XG-EC80L is equipped: One camera per expansion unit
(The CA-EC80HX/CA-EC80L/XG-EC80L can only be connected to the CA-HX500C/HX500M/HX200C/HX200M/HX048C/HX048M.)
Trigger input
Simultaneous capture by up to 4 cameras/individual capture can be selected. (when CA-E800/XG-E800 is not connected, images from up to two
cameras can be captured at the same time)
Main image processor
DSP (High-speed)
DSP
Registered number of inspection settings
SD cards 1 and 2 can each hold 1000 programs (depending on the size of the SD card and the size of the programs), external switching possible
Number of registered screens
Maximum 1000 screens for each program (depending on SD card size),Image compression.
SD card
• SD card slot x 2 (SDHC compatible)
• Compatible with OP-87133 (512MB),
CA-SD1G (1GB: installed standard to SD1),
and CA-SD4G (4GB: SDHC)
• SD card slot x 2 (SDHC compatible)
• Compatible with OP-87133 (512MB: installed standard to SD1), CA-SD1G (1GB), and
CA-SD4G (4GB: SDHC)
Interface
Controlled input (compatible with
arbitrary assignment)
• 20 input (including four high speed inputs designed for trigger input)
• Input rating 26.4 V or lower, 2 mA or greater (3 mA or greater for high speed input terminal)
Controlled output (compatible with
arbitrary assignment)
• 28 output (including four high speed outputs designed for FLASH outputting linked to external device)
• NPN open collector
*1
Maximum 50 mA (30 V or less)
Encoder input
For the Open Collector Output (Dedicated to 24 V outputs) using the Control Input Terminal (2 systems)
Monitor output
Analog RGB Output, XGA (1024 x 768, 24 bit color)/SVGA (800 x 60, 24 bit color) Switch (can be set by the inspection settings unit)
Operation indicators
LED display for Power ON, Operation and ERROR
RS-232C
2 Port up to Maximum baud rate of 230400 bps
The digit output or control input/output and CA Series Touch Panel interface can be switched.
PLC link
• Numerical value output and control input/output using the RS-232C port or Ethernet port enabled (Do not use to connect to CC-Link, EtherNet/IP and
PROFINET.)
• Following PLCs are supported via link unit:
*2
KEYENCE: KV-700 Series, KV-1000 Series, KV-3000 Series, KV-5000 Series, KV-5500 Series, KV Nano Series
Mitsubishi Electric: MELSEC A Series (RS-232C only), Q Series, L Series
OMRON: SYSMAC C Series (RS-232C only), CP1/CS1/CJ1/CJ2 Series
YASKAWA Electric: MP900 Series (RS-232C only), MP2000 Series
Ethernet
• Numerical value output, and control input/output enabled.
• By the connection of KEYENCE PC application software, in addition to the function described above, uploading and downloading the inspection
settings, simulations, data, including image data can be sent or received.
• For the FTP client function, the VNC server function (for clients other than for PC it will be only for the screen display), and BOOTP function.
• 1000BASE-T/100BASE-TX/10BASE-T
USB
• By the connection of KEYENCE PC application software, in addition to numerical value output and control input/output , uploading and
downloading the inspection settings, simulations, data, including image data can be sent or received
• USB2.0
CC-Link
• By connecting the optional CC-Link expansion unit CA-NCL10E, numerical value input/output and control input/output are enabled. (Do not use to
connect to PLC Link, EtherNet/IP and PROFINET.)
• Compatible to the Ver.1.10 remote device station, Ver.2.00 remote device station
EtherNet/IP
Numerical value input/output, and control input/output by using the Ethernet port enabled. (Do not use to connect to CC-Link, PLC Link and
PROFINET.)
• Compatible to the cyclic communication (max.1436 byte), and message communication
• Maximum number of connections 32
• Compatible with the conformance test Version.CT10
PROFINET
Numerical value input, and control input/output by using the Ethernet port enabled.
• Compatible to the cyclic communication (max. 1408 byte)
• Compatible to the aperiodic (recorded data) communication
• Compatible with the Conformance Class A
• Do not use to connect to PLC Link, CC-Link and EtherNet/IP.
Console
• By the optional OP-84231, OP-84236 (without silk screen printing), various menu can be used
• Compatible to the operation assignment settings to the console button
• Compatible to the button activation and deactivation of each user group
Touch Panel
• Setting operation from the CA Series touch panel used by the RS-232 port is possible
• For the dedicated touch menu or the operation button
Display language
Japanese/English/Simplified Chinese/Traditional Chinese/German selectable
(Choose the default language to be used when turning power ON)
Illumination control
By connecting the optional illumination expansion unit CA-DC30E/DC21E, the lighting and light intensity of the LED illumination (12 V, 24 V) can be
controlled, there are two channels per unit, and a maximum of four units can be connected. By connecting the illumination expansion unit
CA-DC30E, the lighting and light intensity of the LED illumination (12 V, 24 V) can be controlled, there are two channels per unit, and a maximum of
two units can be connected.
Rating
Power source voltage
24 VDC ±10%
Consumption current
3.6 A (2 Cameras)/ 4.6 A (4 Cameras), when either one is turned ON, at the time of maximum load including the input current.
Environmental
resistance
Ambient temperature
0 to +45°C
Ambient operating humidity
35 to 85% RH (no condensation)
Weight
Approx. 1600 g