Main Specifications

Model type

XG-8700/8702

XG-8500/8502

XG-8000/8002

Pixels

• With CA-HX500C/HX500M connected

5 mega-pixel mode: 2432(H) x 2040(V),

approx. 4.96 mega-pixels

2 mega-pixel mode: 1600(H) x 1200(V),

approx. 1.92 mega-pixels

• With CA-HX200C/HX200M connected

2 mega-pixel mode: 1600(H) x 1200(V),

approx. 1.92 mega-pixels

• With CA-HX048C/HX048M connected

470 k pixel mode: 784(H) x 596(V), approx.

470,000 pixels

310 k pixel mode: 640(H) x 480(V), approx.

310,000 pixels

240 k pixel mode: 512(H) x 480(V), approx.

240,000 pixels

• With XG-H500C/H500M connected

5 mega-pixel mode: 2432(H) x 2050(V),

approx. 4.99 mega-pixels

• With XG-200C/S200C/H200C/200M/S200M/

H200M connected

2 mega-pixel mode: 1600(H) x 1200(V),

approx. 1.92 mega-pixels

1 mega-pixel mode: 1024(H) x 960(V),

approx. 980,000 pixels

• With XG-H100C/H100M connected

1000(H) x 1000(V), 1 mega-pixel

• With XG-035C/S035C/H035C/035M/S035M/

H035M connected

310 k pixel mode: 640(H) x 480(V), approx.

310,000 pixels

240 k pixel mode: 512(H) x 480(V), approx.

240,000 pixels

• With CA-HX200C/HX200M connected

2 mega-pixel mode: 1600(H) x 1200(V),

approx. 1.92 mega-pixels

• With CA-HX048C/HX048M connected

470 k pixel mode: 784(H) x 596(V), approx.

470,000 pixels

310 k pixel mode: 640(H) x 480(V), approx.

310,000 pixels

240 k pixel mode: 512(H) x 480(V), approx.

240,000 pixels

• With XG-200C/S200C/H200C/200M/S200M/

H200M connected

2 mega-pixel mode: 1600(H) x 1200(V),

approx. 1.92 mega-pixels

1 mega-pixel mode: 1024(H) x 960(V),

approx. 980,000 pixels

• With XG-H100C/H100M connected

1000(H) x 1000(V), 1 mega-pixel

• With XG-035C/S035C/H035C/035M/S035M/

H035M connected

310 k pixel mode: 640(H) x 480(V), approx.

310,000 pixels

240 k pixel mode: 512(H) x 480(V), approx.

240,000 pixels

• With CA-HX048C/HX048M connected

470 k pixel mode: 784(H) x 596(V), approx.

470,000 pixels

310 k pixel mode: 640(H) x 480(V), approx.

310,000 pixels

240 k pixel mode: 512(H) x 480(V), approx.

240,000 pixels

• With XG-035C/S035C/H035C/035M/S035M/

H035M connected

310 k pixel mode: 640(H) x 480(V), approx.

310,000 pixels

240 k pixel mode: 512(H) x 480(V), approx.

240,000 pixels

Camera input

Two color/monochrome cameras (Compatible

with CA-HX500C/HX500M/HX200C/HX200M/

HX048C/HX048M and XG-H500C/200C/

S200C/H200C/H100C/035C/S035C/H035C/

H500M/200M/S200M/H200M/H100M/035M/

S035M/H035M, mixed connection possible)

Two color/monochrome cameras (Compatible

with CA-HX200C/HX200M/HX048C/HX048M

and XG-200C/S200C/H200C/H100C/035C/

S035C/H035C/200M/S200M/H200M/H100M/

035M/S035M/H035M, mixed connection

possible)

Two color/monochrome cameras (CA-HX048C/

HX048M and XG-035C/S035C/H035C/035M/

S035M/H035M can be connected.Mixed

connection is possible.)

By using expansion unit CA-E800/XG-E800, up to four cameras can be connected (mixed connection is possible).

When the CA-EC80/XG-EC80 is equipped: Two cameras per expansion unit

When the CA-EC80HX/CA-EC80L/XG-EC80L is equipped: One camera per expansion unit

(The CA-EC80HX/CA-EC80L/XG-EC80L can only be connected to the CA-HX500C/HX500M/HX200C/HX200M/HX048C/HX048M.)

Trigger input

Simultaneous capture by up to 4 cameras/individual capture can be selected. (when CA-E800/XG-E800 is not connected, images from up to two

cameras can be captured at the same time)

Main image processor

DSP (High-speed)

DSP

Registered number of inspection settings

SD cards 1 and 2 can each hold 1000 programs (depending on the size of the SD card and the size of the programs), external switching possible

Number of registered screens

Maximum 1000 screens for each program (depending on SD card size),Image compression.

SD card

• SD card slot x 2 (SDHC compatible)

• Compatible with OP-87133 (512MB),

CA-SD1G (1GB: installed standard to SD1),

and CA-SD4G (4GB: SDHC)

• SD card slot x 2 (SDHC compatible)

• Compatible with OP-87133 (512MB: installed standard to SD1), CA-SD1G (1GB), and

CA-SD4G (4GB: SDHC)

Interface

Controlled input (compatible with

arbitrary assignment)

• 20 input (including four high speed inputs designed for trigger input)

• Input rating 26.4 V or lower, 2 mA or greater (3 mA or greater for high speed input terminal)

Controlled output (compatible with

arbitrary assignment)

• 28 output (including four high speed outputs designed for FLASH outputting linked to external device)
• NPN open collector

*1

Maximum 50 mA (30 V or less)

Encoder input

For the Open Collector Output (Dedicated to 24 V outputs) using the Control Input Terminal (2 systems)

Monitor output

Analog RGB Output, XGA (1024 x 768, 24 bit color)/SVGA (800 x 60, 24 bit color) Switch (can be set by the inspection settings unit)

Operation indicators

LED display for Power ON, Operation and ERROR

RS-232C

2 Port up to Maximum baud rate of 230400 bps

The digit output or control input/output and CA Series Touch Panel interface can be switched.

PLC link

• Numerical value output and control input/output using the RS-232C port or Ethernet port enabled (Do not use to connect to CC-Link, EtherNet/IP and

PROFINET.)

• Following PLCs are supported via link unit:

*2

KEYENCE: KV-700 Series, KV-1000 Series, KV-3000 Series, KV-5000 Series, KV-5500 Series, KV Nano Series

Mitsubishi Electric: MELSEC A Series (RS-232C only), Q Series, L Series

OMRON: SYSMAC C Series (RS-232C only), CP1/CS1/CJ1/CJ2 Series

YASKAWA Electric: MP900 Series (RS-232C only), MP2000 Series

Ethernet

• Numerical value output, and control input/output enabled.

• By the connection of KEYENCE PC application software, in addition to the function described above, uploading and downloading the inspection

settings, simulations, data, including image data can be sent or received.

• For the FTP client function, the VNC server function (for clients other than for PC it will be only for the screen display), and BOOTP function.

• 1000BASE-T/100BASE-TX/10BASE-T

USB

• By the connection of KEYENCE PC application software, in addition to numerical value output and control input/output , uploading and

downloading the inspection settings, simulations, data, including image data can be sent or received

• USB2.0

CC-Link

• By connecting the optional CC-Link expansion unit CA-NCL10E, numerical value input/output and control input/output are enabled. (Do not use to

connect to PLC Link, EtherNet/IP and PROFINET.)

• Compatible to the Ver.1.10 remote device station, Ver.2.00 remote device station

EtherNet/IP

Numerical value input/output, and control input/output by using the Ethernet port enabled. (Do not use to connect to CC-Link, PLC Link and

PROFINET.)

• Compatible to the cyclic communication (max.1436 byte), and message communication

• Maximum number of connections 32

• Compatible with the conformance test Version.CT10

PROFINET

Numerical value input, and control input/output by using the Ethernet port enabled.

• Compatible to the cyclic communication (max. 1408 byte)

• Compatible to the aperiodic (recorded data) communication

• Compatible with the Conformance Class A

• Do not use to connect to PLC Link, CC-Link and EtherNet/IP.

Console

• By the optional OP-84231, OP-84236 (without silk screen printing), various menu can be used

• Compatible to the operation assignment settings to the console button

• Compatible to the button activation and deactivation of each user group

Touch Panel

• Setting operation from the CA Series touch panel used by the RS-232 port is possible

• For the dedicated touch menu or the operation button

Display language

Japanese/English/Simplified Chinese/Traditional Chinese/German selectable

(Choose the default language to be used when turning power ON)

Illumination control

By connecting the optional illumination expansion unit CA-DC30E/DC21E, the lighting and light intensity of the LED illumination (12 V, 24 V) can be

controlled, there are two channels per unit, and a maximum of four units can be connected. By connecting the illumination expansion unit

CA-DC30E, the lighting and light intensity of the LED illumination (12 V, 24 V) can be controlled, there are two channels per unit, and a maximum of

two units can be connected.

Rating

Power source voltage

24 VDC ±10%

Consumption current

3.6 A (2 Cameras)/ 4.6 A (4 Cameras), when either one is turned ON, at the time of maximum load including the input current.

Environmental

resistance

Ambient temperature

0 to +45°C

Ambient operating humidity

35 to 85% RH (no condensation)

Weight

Approx. 1600 g

Advertising