3 Installer Guide

Provide Power

• For 24 Volt AC power, you must connect the common side of the transformer to the C terminal on the
thermostat sub-base. In dual transformer installations, the transformer common must come from the
cooling transformer.
• For battery power, insert the 2 supplied “AA” type alkaline batteries into the battery compartment located in
the rear housing of the thermostat. Make sure to position the Positive (+) and Negative (-) sides of the batteries
correctly with the +/- symbols in the battery compartment.

C

+

+

24VAC Power Terminal (C)

Batteries Installed as Shown

2

Wiring Terminations for model 6100

Terminal Function

Description

G

Output

Fan Control

Rc

Input

24 Volt AC Cooling Transformer

(Dual Transformer Systems Only)

Rh

Input

Power Connection (24 Volt AC Heating

Transformer or Millivolt Power Source)

W

Output

1st Stage Conventional Heat

O or B

Output

Reversing Valve (Cool Active or Heat Active)

Y

Output

1st Stage Compressor

C

Input

24 Volt AC Transformer Common

S1

S2

Connecting Your Wires

3

Input

Optional Remote Sensor (Indoor or Outdoor)