Operation, Do not overload generator, Operation at high altitude – Champion Power Equipment 40710 User Manual
Page 15
REV 40710-20131225
12
40710
ENGLISH
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the running and
starting watts necessary for your purposes.
1. Select the electrical devices you plan on running at
the same time.
2. Total the running watts of these items. This is
the amount of power you need to keep your items
running.
3. Identify the highest starting wattage of all devices
identified in step 1. Add this number to the number
calculated in step 2. Surge wattage is the extra
burst of power needed to start some electric driven
equipment. Following the steps listed under “Power
Management” will guarantee that only one device will
be starting at a time.
Power Management
Use the following formula to convert voltage and
amperage to watts:
Volts x Amps = Watts
To prolong the life of your generator and attached
devices, follow these steps to add electrical load:
1. Start the generator with no electrical load attached
2. Allow the engine to run for several minutes to stabilize.
3. Plug in and turn on the first item. It is best to attach
the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
Never exceed the specified capacity when adding
loads to the generator.
NOTE
Operation at High Altitude
The density of air at high altitude is lower than at sea
level. Engine power is reduced as the air mass and
air-fuel ratio decrease. Engine power and output will
be reduced approximately 3½% for every 1000 feet of
elevation above sea level. This is a natural trend and
cannot be changed by adjusting the engine.
OPERATION