Eagle Microsystems EI-2000 User Manual

Page 6

Advertising
background image


MODE 2: ADJUSTABLE REMAINING
Typical application: drum scales - Remaining & gross weights are displayable.

1.

An empty scale should read zero. If it does not, press the ZERO pushbutton. If
“no 0” is displayed, access the calibration mode to zero the scale.

2.

Place container with product on the scale.

3.

Instrument will show the REMAINING weight and will flash the tare LED.

4.

Use the UP and DOWN arrow pushbuttons to adjust the remaining weight
displayed.

5.

Press the SELECT pushbutton, the tare LED will stop flashing.


If you need to adjust the REMAINING weight again, press and hold either the UP or DOWN
arrow pushbutton for 3 seconds, the tare LED will start to flash and the remaining weight will
now be adjustable. Press the SELECT pushbutton when finished.

MODE 3: AUTOMATIC OPERATION
Typical application: full cylinders/tanks - Remaining and gross weights are displayable.

1.

An empty scale should read zero. If it does not, press the ZERO pushbutton. If
“no 0” is displayed, access the calibration mode to zero the scale.

2.

Place a full container on the scale; the Gross LED will flash.

3.

Adjust gross weight by using the UP and DOWN arrow pushbuttons.

4.

Press the SELECT pushbutton; the tare weight will be automatically calculated
and stored in memory. The preset “START” value (configuration parameter
Px17) of remaining chlorine weight will now be displayed, and the REMAIN LED
is illuminated.


If the REMAINING weight must be adjusted again, one should press and hold either the UP
or DOWN arrow pushbutton for 3 seconds. The tare LED will start to flash and the remaining
weight will now be adjustable. Press the SELECT pushbutton when finished.


MODE 4: ADJUSTABLE TARE
Typical application: partially used chlorine cylinders - Remaining, tare, & gross weights are
displayable.

1.

An empty scale should read zero. If it does not, press the ZERO pushbutton. If
“no 0” is displayed, access the calibration mode to zero the scale.

2.

Place a full container on the scale.

3.

The Gross LED will flash.

4.

Adjust gross weight by using the UP and DOWN arrow pushbuttons.

5.

Press SELECT, tare will now be displayed (tare LED should be illuminated).

6.

Adjust tare, as required, by using the UP and DOWN arrow pushbuttons.

7.

Press SELECT, the remaining weight will now be displayed (REMAIN LED
should be illuminated).

Advertising