2. The hook-up cable to the read-out should not run close to other unshielded cables. Display
instability may result.
3. For best accuracy, a flat, level, and rigid surface is recommended to support the scale.
5.
The area should be accessible for periodic cleaning.
2.4 INSTALLING ( refer to LP4310 Outline & Interconnect Dwg. at the end of this manual)
1.
Clean the site area of dirt and debris.
2.
The scale should be oriented so that loading will be from the hinge side of the scale. Secure the 2
“hinge brackets” to the floor with four (4) appropriately selected 3/8” diameter anchor bolts.
3. With the bottom of the scale exposed, install the leveling foot in the load cell. Screw the foot all
the way untill it bottoms out on the load cell.
2.5 LEVELING
Fig. 2: Detail showing easy leveling adjustments
with scale in place. A screw driver is the only tool needed.
1. For best scale performance scale should be level within 1/2 degree.
.
2.6 HOOK-UP CABLE
Table 1 shows the wiring connections necessary to attach the platform to the read-out instrument. The
color code and function are as noted.
C O L O R
FUNCTION
B L A C K
– EXCITATION
W H I T E
– SIGNAL
G R E E N
+ SIGNAL
R E D
+ EXCITATION
Table 1
SECTION 3.0 TROUBLE SHOOTING
The following is a list of potential problems and likely cures.
SLOT TYPE
SCREW DRIVER
ADJUSTMENT
ACCESS HOLE
FOOT