3.2 Nominal data

Motor

M2E068-CF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

fa

fa

Valid for approval /
standard

CE

CE

Speed / min

-1

1150

1050

Power input / W

130

130

Current draw / A

0.58

0.58

Motor capacitor / µF

2

2

Capacitor voltage / VDB

400

400

Capacitor standard

P2 (CE)

P2 (CE)

Min. back pressure / Pa

0

0

Max. ambient
temperature / °C

50

40

Starting current / A

0.57

0.59

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Technical features

Mass

2.3 kg

Size

140 mm

Surface of rotor

Uncoated

Material of impeller

PP plastic, white

Housing material

PP plastic, black

Motor suspension

Motor mounted via brackets on one side

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44

Insulation class

"F"

Humidity class

F0

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Speed steps

4

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Electrical leads

Via terminal box, integrated capacitor
connected via terminal box; With plug

Motor protection

Thermal overload protector (TOP) wired
internally

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

Approval

CCC; VDE

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C