Operating instructions – ebm-papst D2E146-HS97-03 User Manual
Page 5
Operating instructions
D2E146-HS97-03
Translation of the original operating instructions
3.2 Nominal data
Motor
M2E068-DF
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Type of data definition
fa
ml
Valid for approval /
standard
CE
CE
Speed / min
-1
1350
1750
Power input / W
195
215
Current draw / A
0.86
0.94
Motor capacitor / µF
5
5
Capacitor voltage / VDB
400
400
Capacitor standard
P2 (CE)
P2 (CE)
Min. back pressure / Pa
0
150
Min. ambient temperature
/ °C
-25
-25
Max. ambient temperature
/ °C
45
40
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
No
Specific ratio
*
1.00
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
/ %
25.6
25.6
32.6
Efficiency grade N
37
37
44
Power input P
e
/ kW
0.16
Air flow q
v
/ m³/h
455
Pressure increase total p
sf
/ Pa
331
Speed n / min
-1
2315
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
3 kg
Size
146 mm
Surface of rotor
Partially cast in aluminium
Material of terminal box
PP plastic, black
Material of impeller
PP plastic, white
Housing material
PP plastic, black
Motor suspension
Motor anti-vibration mounted on both sides
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 20
Insulation class
"F"
Humidity class
F0
Mounting position
Any
Condensate discharge
holes
None, open rotor
Operation mode
S1
Motor bearing
Ball bearing
Speed steps
4
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Electrical leads
Via terminal box, integrated capacitor
connected via terminal box; With plug
Motor protection
Thermal overload protector (TOP) wired
internally
Cable exit
Variable
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-2-31; CE
Approval
CCC; VDE
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 11072-5-9970 · Revision 72138 · Release 2013-07-24 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com