Technical specifications, What to do "when – Fieldmann FVC 2001-EC User Manual

Page 8

Advertising
background image

EN

7

FVC 2001-EC / FVC 2003-EK

Technical specifi cations | What to do "When..."

6. TECHNICAL SPECIFICATIONS

FVC 2001-EK

FVC 2003-EK

Voltage/Frequency

230 V ~ 50 HZ

230 V ~ 50 HZ

Power input

250 W

400 W

Maximum transferred amount

5000 l/h

7500 l/h

Maximum delivery

6 m

5 m

Maximum submersible depth

5 m

5 m

Maximum temperature of the media

35 °C

35 °C

Maximum value of solid particles in the media

Dia. 5 mm

Dia. 35 mm

Height of the switching point: On

Approx. 50 cm

Approx. 50 cm

Height of the switching point: Turned off

Approx. 5 cm

Approx. 5 cm

7. WHAT TO DO "WHEN..."

When...

Causes

Repairs

The pump does not start

– No power supply
– The fl oat does not switch

– Check the power supply
– Move the fl oat to a higher position

Not fl owing

– The suction sieve is clogged

– The pressure hose is bent

– Flush out the suction sieve with

a current of water

– Straighten the hose

The pump does not
turn off

– The fl oat cannot fall lower

– Place the pump correctly

on the fl oor of the tank

Insuffi cient fl ow

– The suction sieve is clogged
– Lowered pump capacity due to dirty

and silted water

– Clean the suction sieve
– Clean the pump and fl ush the hose

with clean water

The pump turns off
after a short time

– The temperature fuse stops the

pump due to dirty water

– The water is too hot. The temperature

fuse stops the pump

– Disconnect the power plug.

Clean the pump and the pumping pit

– Check that the maximum water

temperature of 35 °C is not exceeded

Note: Not covered by warranty:

Damage to the rotating mechanical gasket caused by running the pump empty, or by foreign objects

in the water

Blocking of the running wheel by foreign objects
Damage during transport
Damage caused by unprofessional alterations by persons

Advertising