5.3.3 Schedule

Please refer to chapter 4.4 schedule.

5.3.4 RS232

RS232 interface is shown as below. There are five items. See

X363H363H363H333H333H333H340H303H

Figure 5-8

z

Function: There are various devices for you to select. Console is for serial port or min-end

platform to upgrade program. Keyboard is for you to use special keyboard to control current
device.

z

Baud rate: You can select proper baud rate.

z

Data bit: You can select proper data bit. The value ranges from 5 to 8.

z

Stop bit: There are three values: 1/1.5/2.

z

Parity: there are three choices: none/odd/even.

System default setup is:
z

Function:

Console

z

Baud

rate:115200

z

Data

bit:8

z

Stop

bit:1

z

Parity:

None

After completing all the setups please click save button, system goes back to the previous menu.

Figure 5-8


5.3.5 Network

Here is for you to input network information. See

X364H364H364H334H334H334H341H304H

Figure 5-9.

X

z

IP address: Here you can input IP address.

z

DHCP: It is to auto search IP. When enable DHCP function, you can not modify IP/Subnet

mask /Gateway. These values are from DHCP function. If you have not enabled DHCP
function, IP/Subnet mask/Gateway display as zero. You need to disable DHCP function to
view current IP information. Besides, when PPPoE is operating, you can not modify
IP/Subnet mask /Gateway.

z

TCP port: Default value is 37777.

z

UDP port: Default value is 37778.

z

HTTP port: Default value is 80.

z

Max connection: system support maximal 10 users. 0 means there is no connection limit.

z

Transfer mode: Here you can select the priority between fluency/video qualities.